Total ellipse of the heart valve: the impact of eccentric stent distortion on the regional dynamic deformation of pericardial tissue leaflets of a transcatheter aortic valve replacement.
نویسندگان
چکیده
Transcatheter aortic valve replacements (TAVRs) are a percutaneous alternative to surgical aortic valve replacements and are used to treat patients with aortic valve stenosis. This minimally invasive procedure relies on expansion of the TAVR stent to radially displace calcified aortic valve leaflets against the aortic root wall. However, these calcium deposits can impede the expansion of the device causing distortion of the valve stent and pericardial tissue leaflets. The objective of this study was to elucidate the impact of eccentric TAVR stent distortion on the dynamic deformation of the tissue leaflets of the prosthesis in vitro. Dual-camera stereophotogrammetry was used to measure the regional variation in strain in a leaflet of a TAVR deployed in nominal circular and eccentric (eccentricity index = 28%) orifices, representative of deployed TAVRs in vivo. It was observed that (i) eccentric stent distortion caused incorrect coaptation of the leaflets at peak diastole resulting in a 'peel-back' leaflet geometry that was not present in the circular valve and (ii) adverse bending of the leaflet, arising in the eccentric valve at peak diastole, caused significantly higher commissure strains compared with the circular valve in both normotensive and hypertensive pressure conditions (normotension: eccentric = 13.76 ± 2.04% versus circular = 11.77 ± 1.61%, p = 0.0014, hypertension: eccentric = 15.07 ± 1.13% versus circular = 13.56 ± 0.87%, p = 0.0042). This study reveals that eccentric distortion of a TAVR stent can have a considerable impact on dynamic leaflet deformation, inducing deleterious bending of the leaflet and increasing commissures strains, which might expedite leaflet structural failure compared to leaflets in a circular deployed valve.
منابع مشابه
The effects of transcatheter valve crimping on pericardial leaflets.
BACKGROUND Transcatheter aortic valve replacement has emerged as a promising therapy for treatment of severe aortic stenosis. Although it has been shown that these valves can be safely delivered and implanted, studies of valve longevity are lacking because of the infancy of the technology. Particularly, the effects of stent crimping on the valve's leaflets have not yet been sufficiently investi...
متن کاملTranscatheter Aortic Valve Replacement: A Review Article
Transcatheter aortic valve replacement (TAVR) is a novel therapeutic intervention for the replacement of severely stenotic aortic valves in high-risk patients for standard surgical procedures. Since the initial PARTNER trial results, use of TAVR has been on the rise each year. New delivery methods and different valves have been developed and modified in order to promote the minimally invasive p...
متن کاملHigh-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient
Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...
متن کاملHealth-Related Quality of Life after Valve Replacement Surgery
Background: Heart valve disease gradually increases the pressure in the heart chambers and impairs heart pumping. It influences on quality of life due to low output, disability, fear, amnesia, anxiety, and depression. Although most of signs and symptoms in patients with heart valve diseases may significantly decrease after valve replacement surgery, there is limited information about the impact...
متن کاملThree Different Imaging Modalities of a Patient with the Aortic Coarctation
The patient was a 19 year-old woman with the diagnosis of resistant hypertension, although she was under treatment of three classes of anti-hypertensive drugs (beta blocker, angiotensin receptor blocker, diuretic) for more than one year. In physical examination there was only a significant difference between the systolic blood pressure of upper and lower extremities (200 vs. 120 mmHg), without ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of the Royal Society, Interface
دوره 12 113 شماره
صفحات -
تاریخ انتشار 2015