Whole blood pumping with a microthrottle pump.
نویسندگان
چکیده
We have previously reported that microthrottle pumps (MTPs) display the capacity to pump solid phase suspensions such as polystyrene beads which prove challenging to most microfluidic pumps. In this paper we report employing a linear microthrottle pump (LMTP) to pump whole, undiluted, anticoagulated, human venous blood at 200 μl min(-1) with minimal erythrocyte lysis and no observed pump blockage. LMTPs are particularly well suited to particle suspension transport by virtue of their relatively unimpeded internal flow-path. Micropumping of whole blood represents a rigorous real-world test of cell suspension transport given blood's high cell content by volume and erythrocytes' relative fragility. A modification of the standard Drabkin method and its validation to spectrophotometrically quantify low levels of erythrocyte lysis by hemoglobin release is also reported. Erythrocyte lysis rates resulting from transport via LMTP are determined to be below one cell in 500 at a pumping rate of 102 μl min(-1).
منابع مشابه
A Strip-Type Microthrottle Pump: Modeling, Design and Fabrication
A novel design for a strip-type microthrottle pump with a rectangular actuator geometry is proposed, with more efficient chip surface consumption compared to existing micropumps with circular actuators. Due to the complex structure and operation of the proposed device, determination of detailed structural parameters is essential. Therefore, we developed an advanced, fully coupled 3D electro-flu...
متن کاملWaterhammer Caused by Intermittent Pump Failure in Pipe Systems Including Parallel Pump Groups
The use of pumps linked in parallel or series in large scale pipe systems is usually inevitable, to meet the required head and discharge. Transient flow occurs following a pump failure in a pump group as a result of variations in the flow rate. This research is an investigation about waterhammer caused by one or more pump-switch off in a pump group when they are connected in parallel. The opera...
متن کاملEstimation of the Discharge of wells Electro-pump through Energy Consumption and Pumping Head Parameters (Case Study: South Khorasan Province, Iran)
For managing the discharge of water resource, utilizing high precision measuring instruments and workers is necessary that can be lead to high cost on the governments. The purpose of this paper is to present a new approach that can provide a good estimation of the well water discharge without human intervention and the use of measuring equipment. In this research, 38 wells with suitable conditi...
متن کاملAssociation of the whole blood potassium polymorphism with resistant to saline in two sheep breeds of different climates of Iran
Abstract The whole blood potassium concentration has shown the bimodal distribution in sheep, which has been classified into LK and HK types; HK allele is recessive to LK with a single gene inheritance. This polymorphism showed different behavior in different environment, which could be due to adaptation process. This research was conducted on the Zel and kermani breed research station, which...
متن کاملSimulation of Direct Pumping of Quantum Dots in a Quantum Dot Laser
In this paper, the nonlinear rate equations governing a quantum dot laser isused to simulate the transient as well as the steady-state behaviors of the laser.Computation results show that the rate equations are capable of simulating true behaviorof a quantum dot laser. Then, the pump rates of the rate equations (which show indirectelectrical pumping of the quantum dots through a wetting layer) ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Biomicrofluidics
دوره 4 4 شماره
صفحات -
تاریخ انتشار 2010