Poor relation between biomechanical and clinical studies for the proximal femoral locking compression plate

نویسندگان

  • Bjarke Viberg
  • Katrine M V Rasmussen
  • Søren Overgaard
  • Cecilia Rogmark
چکیده

Background and purpose - The proximal femur locking compression plate (PF-LCP) is a new concept in the treatment of hip fractures. When releasing new implants onto the market, biomechanical studies are conducted to evaluate performance of the implant. We investigated the relation between biomechanical and clinical studies on PF-LCP. Methods - A systematic literature search of relevant biomechanical and clinical studies was conducted in PubMed on December 1, 2015. 7 biomechanical studies and 15 clinical studies were included. Results - Even though the biomechanical studies showed equivalent or higher failure loads for femoral neck fracture, the clinical results were far worse, with a 37% complication rate. There were no biomechanical studies on pertrochanteric fractures. Biomechanical studies on subtrochanteric fractures showed that PF-LCP had a lower failure load than with proximal femoral nail, but higher than with angled blade plate. 4 clinical studies had complication rates less than 8% and 9 studies had complication rates between 15% and 53%. Interpretation - There was no clear relation between biomechanical and clinical studies. Biomechanical studies are generally inherently different from clinical studies, as they examine the best possible theoretical use of the implant without considering the long-term outcome in a clinical setting. Properly designed clinical studies are mandatory when introducing new implants, and they cannot be replaced by biomechanical studies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate

  Background: There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. Methods: Forty patients with valgus knee malalignment were randomly assigned to two equal nu...

متن کامل

Supracondylar Osteotomy in Valgus Knee: Angle Blade Plate Versus Locking Compression Plate.

BACKGROUND There are few studies comparing the biomechanical properties of angled blade plate and locking compression plates in supracondylar osteotomy. In the current randomized study, we prospectively compared the clinical and radiological outcomes of supracondylar osteotomy using these two plates. METHODS Forty patients with valgus knee malalignment were randomly assigned to two equal numb...

متن کامل

Proximal femoral locking compression plate for proximal femoral fractures.

PURPOSE To review short-term outcomes of proximal femoral locking compression plate (PF-LCP) fixation for proximal femoral fractures in terms of postoperative complications and failure rates. METHODS Medical records of 21 men and 5 women aged 22 to 85 (mean, 49.7) years who underwent internal fixation with the PF-LCP for proximal femoral fractures were reviewed. Younger patients (mean age, 38...

متن کامل

Challenges of Plate Fixation for Vancouver Type-C Fractures after a Well-Fixed Hip Arthroplasty Femoral Stem

The fixation of distal femoral fractures (Vancouver type-C fractures) following a well-fixed hip arthroplasty femoral stem has become a challenging issue for orthopedic surgeons due to the inter-prosthetic biomechanical effects such as negative, positive, and torsional strain. Surgeons have applied a range of constructs to overcome these difficulties. To minimize the risk of inter-prosthetic fr...

متن کامل

Proximal Femur Locking Plate for Sub-Trochanteric Femur Fractures: Factors Associated with Failure

INTRODUCTION Proximal femur locking compression plates (PF-LCP) have gained popularity since their inception due to superior biomechanical stability and durability but clinical experience has shown conflicting results including implant failure. OBJECTIVE To study the incidence of implant failure in patients with sub-trochanteric fractures managed with proximal femoral locking compression plat...

متن کامل