The effect of intracranial stent implantation on the curvature of the cerebrovasculature.
نویسندگان
چکیده
BACKGROUND AND PURPOSE Recently, the use of stents to assist in the coiling and repair of wide-neck aneurysms has been shown to be highly effective; however, the effect of these stents on the RC of the parent vessel has not been quantified. The purpose of this study was to quantify the effect of intracranial stenting on the RC of the implanted artery using 3D datasets. MATERIALS AND METHODS Twenty-four patients receiving FDA-approved neurovascular stents to support coil embolization of brain aneurysms were chosen for this study. The stents were located in the ICA, ACA, or MCA. We analyzed C-arm rotational angiography and contrast-enhanced cone beam CT datasets before and after stent implantation, respectively, to ascertain changes in vessel curvature. The images were reconstructed, and the vessel centerline was extracted. From the centerline, the RC was calculated. RESULTS The average implanted stent length was 25.4 ± 5.8 mm, with a pre-implantation RC of 7.1 ± 2.1 mm and a postimplantation RC of 10.7 ± 3.5 mm. This resulted in a 3.6 ± 2.7 mm change in the RC due to implantation (P < .0001), more than a 50% increase from the pre-implantation value. There was no difference in the change of RC for the different locations studied. The change in RC was not impacted by the extent of coil packing within the aneurysm. CONCLUSIONS The implantation of neurovascular stents can be shown to have a large impact on the RC of the vessel. This will lead to a change in the local hemodynamics and flow pattern within the aneurysm.
منابع مشابه
Safety, Efficacy and Clinical Outcome of Direct Stent Implantation
Conventional methods of stenting require predilatation, which potentially increase vessel wall injury and cost of the procedure. In this study, the safety and efficacy of direct AVE-S7 (Medtronic-USA) stent placement were evaluated in 100 patients. Quantitative coronary angiography was performed at the baseline and post-stent. Clinical follow-up was done up to 9 months. In 100 patients (76 male...
متن کاملApplication of 64-slice spiral computed tomography angiography in a follow-up evaluation after coronary stent implantation: A Chinese clinical study
Background: This study assessed the application value of 64-slice spiral computed tomography angiography (CTA) in a follow-up evaluation of patients receiving coronary stent implantation. Materials and Methods: A total of 468 patients who underwent percutaneous coronary intervention (PCI) at our hospital between January 2013 and October 2016 were selected for this study. Coronary angiography an...
متن کاملAcquired Infrarenal Abdominal Aortic Coarctation: Treatment with Percutaneous Self Expandable Stent
Abdominal aortic coarctation is an extremely rare vascular pathology. Its etiology can be congenital or acquired. Here we present a case of acquired infrarenal abdominal coarctation in a 66-year-old woman who complained of low back and legs pain. She had no signs of resting lower limb ischemia, with diminished distal pulses and normal blood pressure in upper and lower extremities. Magnetic reso...
متن کاملبررسی نتیجه کلینیکی بلند مدت آنژیوپلاستی با استنت فلزی در بیماران مبتلا به بیماری عروق کرونر در بیمارستان فاطمه زهرا (س) ساری از سال 1383 تا سال 1385
Background and Purpose:Coronary artery Stenting is known to improve the outcome for ischemic heart disease. Many clinical studies have been performed to determine the long-term outcome of coronary Stenting and most of them were based on first-generation bare-metal Stents. The aim of this study is to evaluate long-term (24 6.4 month) results of second-generation bare metal stent. Materials an...
متن کاملCurvature Effects on Thermal Buckling Load of DWCNT Under Axial Compression Force
In this article, curvature effects on elastic thermal buckling of double-walled carbon nanotubes under axially compressed force are investigated using cylindrical shell model. Also, the small scale effect is taken into account in the formulation. The dependence of the interlayer van der Waals (vdW) pressure on the change of the curvatures of the inner and outer tubes at that point is considered...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 33 9 شماره
صفحات -
تاریخ انتشار 2012