Comparing the efficacy and safety of a novel monophasic waveform delivered by the passive implantable atrial defibrillator with biphasic waveforms in cardioversion of atrial fibrillation.
نویسندگان
چکیده
BACKGROUND The passive implantable atrial defibrillator (PIAD) (with no battery or discharging capacitor and powered transcutaneously by radio-frequency energy) delivering a novel monophasic low-tilt waveform is more efficacious than the standard monophasic waveform at atrial defibrillation. Standard biphasic (STB) waveforms, however, are more efficacious and safer than monophasic waveforms. This study compared the efficacy and safety of the PIAD waveform with biphasic waveforms. METHODS AND RESULTS Sustained atrial fibrillation (AF) was induced by rapid atrial pacing. Cardioversion was attempted via 2 atrial defibrillation leads. The efficacy of the PIAD was compared with 3 biphasic waveforms (standard, single rounded, and double rounded) at varying voltage settings in 10 pigs. After a synchronized shock, hemodynamic changes between the PIAD, standard biphasic, and monophasic waveforms were compared at 1.5 and 3.0 J in 12 pigs. Myocardial injury (biochemical and histological) after ten 5-J PIAD shocks was compared with a no-shock group in 14 pigs. The PIAD 100-V setting was significantly more efficacious than the STB (100/-50 V: 100% [1.88+/-0.02 J] versus 90% [0.89+/-0.0 J]; P=0.025). No arrhythmic, hemodynamic, or myocardial injury was observed with the PIAD waveform. CONCLUSIONS Defibrillation with the PIAD is more efficacious than with the STB waveform and appears safe. This device could provide a more effective option for cardioversion.
منابع مشابه
Novel passive implantable atrial defibrillator using transcutaneous radiofrequency energy transmission successfully cardioverts atrial fibrillation.
BACKGROUND Conventional methods for cardioversion of atrial fibrillation (AF) to sinus rhythm have numerous difficulties. A novel method for cardioversion using the passive implantable atrial defibrillator (PIAD) was tested in acute animal models. This device does not have a battery or a capacitor to store energy and is activated by transferring RF energy across the skin from an external transm...
متن کاملExternal cardioversion of atrial fibrillation in patients with implanted pacemaker or cardioverter-defibrillator systems: a randomized comparison of monophasic and biphasic shock energy application.
AIMS External cardioversion (ECV) of atrial fibrillation (AF) may damage implanted pacemaker and cardioverter-defibrillator (ICD) systems. This prospective study evaluated the safety and efficacy of ECV comparing mono- to biphasic shock waveforms in patients with implanted rhythm devices. METHODS AND RESULTS Patients with pacemaker or ICD systems and an indication for ECV were randomized to r...
متن کاملCARDIOVASCULAR MEDICINE Comparison of monophasic and biphasic shocks for transthoracic cardioversion of atrial fibrillation
Objective: To compare the efficacy of cardioversion in patients with atrial fibrillation between monophasic damped sine waveform and rectilinear biphasic waveform shocks at a high initial energy level and with a conventional paddle position. Design: Prospective randomised study. Patients and setting: 227 patients admitted for cardioversion of atrial fibrillation to a tertiary referral centre. R...
متن کاملComparison of monophasic and biphasic shocks for transthoracic cardioversion of atrial fibrillation.
OBJECTIVE To compare the efficacy of cardioversion in patients with atrial fibrillation between monophasic damped sine waveform and rectilinear biphasic waveform shocks at a high initial energy level and with a conventional paddle position. DESIGN Prospective randomised study. PATIENTS AND SETTING 227 patients admitted for cardioversion of atrial fibrillation to a tertiary referral centre. ...
متن کاملBiphasic versus monophasic shock waveform for conversion of atrial fibrillation.
Cardioversion of atrial fibrillation (AF) using traditional monophasic shock waveform is unsuccessful in up to 20% of cases, and often requires several shocks of up to 360 J. Based on the success with biphasic shock waveform in converting ventricular fibrillation, it was postulated that biphasic shocks would allow cardioversion with lower energy. In a international multicenter, double-blind, ra...