Pre-procedural imaging of aortic root orientation and dimensions: comparison between X-ray angiographic planar imaging and 3-dimensional multidetector row computed tomography.

نویسندگان

  • Vikram Kurra
  • Samir R Kapadia
  • E Murat Tuzcu
  • Sandra S Halliburton
  • Lars Svensson
  • Eric E Roselli
  • Paul Schoenhagen
چکیده

OBJECTIVES We sought to examine whether contrast-enhanced multidetector row computed tomography (MDCT) allows prediction of X-ray angiographic planes for the root angiogram in the context of transcatheter aortic valve implantation. BACKGROUND Understanding of aortic root orientation relative to the body axis is critical for precise positioning of the stent/valve during transcatheter aortic valve implantation. METHODS Forty patients with severe aortic stenosis underwent conventional X-ray angiography and contrast-enhanced MDCT of the aortic root. Oblique MDCT images of the aortic root, corresponding to X-ray angiographic left anterior oblique (LA)/right anterior oblique (RAO) projections, were created. The cranial/caudal angulation was compared between angiographic and reformatted MDCT images. In addition, root diameter measurements were compared. RESULTS The cranial angulation in the LAO X-ray angiograms (mean LAO: 39+/- 8, n = 38) and matched MDCT images were not significantly different (cranial: 25 +/- 7 vs. 23 +/- 8; p = 0.214). There was a small but significant difference between the caudal angulation in the RAO angiogram (mean RAO: 25 +/- 5, n = 40) and matched CT images (caudal: 21 +/- 9 vs. 29 +/- 10; p = 0.002). The annulus diameter in the LAO projection was not significantly different between X-ray angiography and contrast-enhanced MDCT (2.3 +/- 0.3 vs. 2.4 +/- 0.3; p = 0.052), whereas there was a small but significant difference in the annulus diameter in RAO projections between angiography and MDCT (2.4 +/- 0.3 vs. 2.2 +/- 0.3; p = 0.029). CONCLUSIONS Pre-procedural contrast-enhanced MDCT imaging of the aortic root allows prediction of X-ray angiographic planes and contributes to planning of the transcatheter aortic valve implantation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Integrated 3D Echo-X-Ray navigation to predict optimal angiographic deployment projections for TAVR.

(A) The integrated marking feature allows for the placement of a colored are placed on or near the center of each of the coronary cusps in the en colored markers are individually dragged (table side control, using a stand level of the aortic annulus (left panel). These 2 separate steps result in the (long-axis location) of each coronary cusp of the native aortic valve. (C) to a position such th...

متن کامل

Prediction of optimal deployment projection for transcatheter aortic valve replacement: angiographic 3-dimensional reconstruction of the aortic root versus multidetector computed tomography.

BACKGROUND Identifying the optimal fluoroscopic projection of the aortic valve is important for successful transcatheter aortic valve replacement (TAVR). Various imaging modalities, including multidetector computed tomography (MDCT), have been proposed for prediction of the optimal deployment projection. We evaluated a method that provides 3-dimensional angiographic reconstructions (3DA) of the...

متن کامل

Multimodality Imaging in Transcatheter Mitral Interventions

Both echocardiography (specifically transesophageal echocardiography [TEE]) and multidetector row computed tomography (MDCT) have played an integral role in preprocedural planning for transcatheter aortic valve replacement, heavily influencing the moniker of “multimodality imaging.” The strengths of each modalities are complementary (Table), although there is overlap between the preprocedural a...

متن کامل

Three-dimensional imaging in the context of minimally invasive and transcatheter cardiovascular interventions using multi-detector computed tomography: from pre-operative planning to intra-operative guidance.

The rapid expansion of less invasive surgical and transcatheter cardiovascular procedures for a wide range of cardiovascular conditions, including coronary, valvular, structural cardiac, and aortic disease has been paralleled by novel three-dimensional (3-D) approaches to imaging. Three-dimensional imaging allows acquisition of volumetric data sets and subsequent off-line reconstructions along ...

متن کامل

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • JACC. Cardiovascular interventions

دوره 3 1  شماره 

صفحات  -

تاریخ انتشار 2010