Exposure rates in high-level-control fluoroscopy for image enhancement.

نویسندگان

  • C H Cagnon
  • S H Benedict
  • N J Mankovich
  • J T Bushberg
  • J A Seibert
  • J S Whiting
چکیده

High-level fluoroscopic boost options that exceed conventional exposure limits are available as a means of reducing quantum mottle during angiography. Federal law does not specify exposure limits for such high-level controls but requires specific means of activation to safeguard against inadvertent use. The American Association of Physicists in Medicine recently recommended that high-level exposure rates not exceed 2.58 mC/kg/min (10R/min). At six institution surveyed, maximum exposure rates ranged from 5.42 to 24 mC/kg/min (21-93 R/min). Activation of high-level capability varied from a simple foot switch to a keyed interlock requiring a second operator to engage. There appears to be no industry coherence in high-level control exposure limits as yet, although the Center for Devices and Radiological Health recently initiated an investigatory program.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Patients’ Exposure during Angiography and Angioplasty Procedures in the Angiography Department of Shahid Madani Hospital in Tabriz

Introduction: Coronary angiography and angioplasty procedures lead to significant radiation exposure of patients. In the current study, the average radiation dose to patients during angiography in the Angiography Department of Shahid-Madani Hospital was determined. Materials and Methods: An image intensifier based angiography unit (Philips BH 3000) was used for angiography procedures. The accur...

متن کامل

New automated fluoroscopic systems for pediatric applications

Pediatric patients are at higher risk to the adverse effects from exposure to ionizing radiation than adults. The smaller sizes of the anatomy and the reduced X-ray attenuation of the tissues provide special challenges. The goal of this effort is to investigate strategies for pediatric fluoroscopy in order to minimize the radiation exposure to these individuals, while maintaining effective diag...

متن کامل

A Deep Model for Super-resolution Enhancement from a Single Image

This study presents a method to reconstruct a high-resolution image using a deep convolution neural network. We propose a deep model, entitled Deep Block Super Resolution (DBSR), by fusing the output features of a deep convolutional network and a shallow convolutional network. In this way, our model benefits from high frequency and low frequency features extracted from deep and shallow networks...

متن کامل

A New Iterative Fuzzy-Based Method for Image Enhancement (RESEARCH NOTE)

This paper presents a new filtering approach based on fuzzy-logic which has high performance in mixed noise environments. This filter is mainly based on the idea that each pixel is not allowed to be uniformly fired by each of the fuzzy rules. In the proposed filtering algorithm, the rule membership functions are tuned iteratively in order to preserve the image edges. Several test experiments we...

متن کامل

بررسی میزان پرتو پراکنده Xو دوز دریافتی کارکنان بخش آنژیوگرافی یک بیمارستان نظامی

Background and aims: Using X-ray for diagnostic test, is one of the most important exposure to radiation sources for general population and in particular for radiation workers. Therefore, holding down the pollution at the lowest possible level is very important for protection against the internal exposure. The objective of this study is to survey the scattered X-ray rate and received dose by st...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 178 3  شماره 

صفحات  -

تاریخ انتشار 1991