Comparisons of multiple automated anatomy‐based image‐guidance methods for patient setup before head/neck external beam radiotherapy
نویسندگان
چکیده
The purpose was to assess the variability in automated translational head/neck setup corrections computed from several different imaging modalities and rigid registration methods using patient anatomy. Shifts were calculated using three commercial and one in-house automated rigid registration methods for nine head/neck patients who were imaged with three different image-guidance systems. The mean difference between the daily isocenter shifts determined by the four methods ranged from 2.8 to 12.5 mm for all of the test cases.These differences are much greater than the variability observed for a rigid imaging phantom. Image-guided setup procedures have an uncertainty that depends on the imaging modality, the registration algorithm, the image resolution and the image content. In the absence of an absolute ground truth, the variation in the shifts calculated by several different methods provides a useful estimate of that uncertainty.
منابع مشابه
A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom
Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...
متن کاملImpact of body-mass factors on setup displacement in patients with head and neck cancer treated with radiotherapy using daily on-line image guidance
BACKGROUND To determine the impact of body-mass factors (BMF) before radiotherapy and changes during radiotherapy on the magnitude of setup displacement in patients with head and neck cancer (HNC). METHODS The clinical data of 30 patients with HNC was analyzed using the alignment data from daily on-line on-board imaging from image-guided radiotherapy. BMFs included body weight, body height, a...
متن کاملEvaluation of image-guidance protocols in the treatment of head and neck cancers.
PURPOSE The aim of this study was to assess the residual setup error of different image-guidance (IG) protocols in the alignment of patients with head and neck cancer. The protocols differ in the percentage of treatment fractions that are associated with image guidance. Using data from patients who were treated with daily IG, the residual setup errors for several different protocols are retrosp...
متن کاملEstimation of adequate setup margins and threshold for position errors requiring immediate attention in head and neck cancer radiotherapy based on 2D image guidance
BACKGROUND We estimated sufficient setup margins for head-and-neck cancer (HNC) radiotherapy (RT) when 2D kV images are utilized for routine patient setup verification. As another goal we estimated a threshold for the displacements of the most important bony landmarks related to the target volumes requiring immediate attention. METHODS We analyzed 1491 orthogonal x-ray images utilized in RT t...
متن کاملRadiation-induced Hypothyroidism in Head and Neck Malignancy
Background and Objective: Hypothyroidism is a known consequence of the external beam radiotherapy to the neck encompassing the thyroid gland for over 40 years. The aim of this study was to find out the incidence of hypothyroidism in patients with head and neck cancer treated with radiotherapy, when radia...
متن کامل