Low dose chest CT protocol (50 mAs) as a routine protocol for comprehensive assessment of intrathoracic abnormality

نویسندگان

  • Takeshi Kubo
  • Yoshiharu Ohno
  • Mizuki Nishino
  • Pei-Jan Lin
  • Shiva Gautam
  • Hans-Ulrich Kauczor
  • Hiroto Hatabu
چکیده

PURPOSE To determine the diagnostic capability of low-dose CT (50 mAs) in comparison to standard-dose CT (150 mAs). MATERIALS AND METHODS Fifty-nine consecutive patients underwent two non-contrast chest CT scans with different current-time products (50 and 150 mAs at 120 kVp) on a 64-detector row CT scanner. Three board certified chest radiologists independently reviewed 118 series of 2 mm-thick images (2 series for each of 59 patients) in a random order. The readers assessed abnormal findings including emphysema, ground-glass opacity, reticular opacity, micronodules, bronchiectasis, honeycomb, nodules (>5 mm), aortic aneurysm, coronary artery calcification, pericardial and pleural effusion, pleural thickening, mediastinal tumor and lymph node enlargement. Five-point scale from 1 (definitely absent) to 5 (definitely present) was used to record the results. The rates of score agreement between two images were calculated. Deviation of one observer's score from other two observers was compared between low dose CT and standard dose CT. RESULTS Mean agreement rate of the lung parenchymal findings between low dose CT and standard dose CT images was 0.836 (range, 0.746-0.926). Mean agreement rates for mediastinal and pleural findings were 0.920 (range, 0.735-1.000). There was no statistically significant difference in the deviation of the observers' scores between low-dose CT and standard-dose CT. CONCLUSION Low dose CT protocol at 50 mAs can produce the screening results consistent with standard dose CT protocol (150 mAs), supporting routine use of low dose chest CT protocol.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Clinical Value of Low Dose CT- Scan in Pediatric Chest Diseases: Adequacy Assessment

Background Radiation dose about 400 times that of standard thoracic computed tomography (CT) in comparison with chest X- ray resulting in different approaches to decrease radiation dose have been established in the last few years to prevent possible side effects especially in children, such as low dose protocols. The aim of this study was assessment of clinical v...

متن کامل

بررسی میزان‌ CTDIwوDLP در پروتکل‌های معمول CT دربیمارستان شهید بهشتی کاشان درسال 1393 ومقایسه آن با ‌میزان دز مرجع

The use of computed tomography (CT) as a diagnostic tool has been considerably increased. Therefore, the controlled and protection-based use of the CT scan is necessary to reduce the detrimental effects of radiation. This study was carried out to determine patient dose level in routine CT protocols and measure CTDIW and DLP in routine CT protocols among adult patients in Kashan Shahid Beheshti ...

متن کامل

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...

متن کامل

An assessment of the Doses Received by Children from CT Examinations Along with the QC Parameters from a Conventional CT System

Introduction: In 2000, the UNSCEAR reported that CT constitutes 5% of all the medical x-ray  examinations and it contributes 34% of the resultant collective dose worldwide. Children are more  sensitive to the ionizing radiations than adults. So, routine quality control tests are expected to be  carried out periodically on the CT scanners. The aim of this research was to estimate the effective  ...

متن کامل

Optimization of Head CT Protocol to Reduce the Absorbed Dose in Eye Lenses and Thyroid: A Phantom Study

Introduction: Utilization of computed tomography (CT) scans is increasing annually. This study aimed to reduce the absorbed dose of sensitive organs in the head (eye lenses and thyroid) and to assess changes in resultant images quality in head scans when the radiation dose is decreased. Material and Methods: An anthropomorphic phantom was examined with head protocols in both helical and sectio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2016