Time-resolved Magnetic Resonance Angiography for assessment of recanalization after coil embolization of visceral artery aneurysms

نویسندگان

  • Kenichiro Kurosaka
  • Tatsuya Kawai
  • Masashi Shimohira
  • Takuya Hashizume
  • Kengo Ohta
  • Yosuke Suzuki
  • Yuta Shibamoto
چکیده

BACKGROUND Follow-up imaging after coil embolization of visceral artery aneurysms is important for detecting recanalization. However, CT examination is susceptible to coil artifacts, which sometimes makes it difficult to assess recanalization. We report 2 cases where recanalization was successfully visualized using time-resolved magnetic resonance angiography after coil embolization of visceral artery aneurysms (one case of right internal iliac artery aneurysm and one case of splenic artery aneurysm). Repeat coil embolization was successfully performed. CASE REPORT Case 1. An 80-year-old male patient with right internal iliac artery (IIA) aneurysm underwent coil embolization. Aneurysm was located at the bifurcation of the right IIA and therefore, after making a femorofemoral bypass, the distal part of the right IIA, aneurysm and the common iliac artery were embolized with a coil. One year later, the size of the aneurysm seemed to have increased on CT. However, the details were not determined because of metal artifacts. Thus, time-resolved MRA was performed and showed minute vascular flow inside the aneurysm. Angiography was subsequently performed and blood flow inside the aneurysm was visualized similar to the findings in time-resolved MRA. Coil embolization was performed once more and vascular flow inside the aneurysm disappeared. Case 2. A 36-year-old male patient with a splenic artery aneurysm underwent coil packing with preservation of splenic artery patency. Four years later, coil compaction was suspected in a CT scan, but CT could not evaluate recanalization because of severe metal artifacts. Angiography was subsequently performed, showing recanalization of the aneurysm as did the time-resolved MRA. Therefore, coil embolization of the aneurysm and splenic artery was performed again. CONCLUSIONS Follow-up imaging after coil embolization of visceral artery aneurysms is important for detecting recanalization. However, it is sometimes difficult to assess recanalization with CT because of artifacts caused by metal. In our cases, recanalization of aneurysms was clearly shown by time-resolved MRA and re-embolization was successfully performed. In conclusion, time-resolved MRA appears to be useful in assessment of recanalization of visceral artery aneurysms after coil embolization.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Follow-up of true visceral artery aneurysm after coil embolization by three-dimensional contrast-enhanced MR angiography.

PURPOSE We aimed to evaluate the outcomes of coil embolization of true visceral artery aneurysms by three-dimensional contrast-enhanced magnetic resonance (MR) angiography. MATERIALS AND METHODS We used three-dimensional contrast-enhanced MR angiography, which included source images, to evaluate 23 patients (mean age, 60 years; range, 28-83 years) with true visceral artery aneurysms (splenic,...

متن کامل

Delayed Ischemic Stroke after Flow Diversion of Large Posterior Communicating Artery Aneurysm

For securing large, giant, and wide-neck aneurysms, conventional coil embolization has substantial limitations, such as incomplete occlusion, recanalization, and a high recurrence rate. To overcome these limitations, a novel paradigm was suggested and, as a result, flow-diverting device was developed. The flow-diverting device is an innovative and effective technique to allow securing of large,...

متن کامل

Single-stage Coil Embolization for Kissing Aneurysms of the Internal Carotid Artery Using Enterprise Stent: Three Cases Reports

Purpose: Kissing aneurysms (KAs) are caused by the rare incidence of two aneurysms with different cervixes mutually contacting each other, with craniotomy surgical clipping having been reported as difficult. The objective was to investigate the treatment outcome of single-stage coil embolization using an Enterprise stent for internal carotid artery KA. Materials and Methods: The subjects consis...

متن کامل

Contrast Enhancement of Aneurysm Sac Post-Pipeline Treatment Interpreted as Recanalization

Multiple imaging modalities are available to evaluate aneurysms post-flow diverter (FD) placement. Though digital subtraction angiography (DSA) is the gold standard imaging modality post-FD placement, it is not perfect, and neither are other techniques, including contrast-enhanced magnetic resonance angiography (CE-MRA) and magnetic resonance imaging (MRI). We present a case of a 73-year-old wo...

متن کامل

Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images

OBJECTIVE The aim of this study was to determine the interobserver and intermodality agreement in the interpretation of time-of-flight (TOF) MR angiography (MRA) for the follow-up of coiled intracranial aneurysms with the Enterprise stent. MATERIALS AND METHODS Two experienced neurointerventionists independently reviewed the follow-up MRA studies of 40 consecutive patients with 44 coiled aneu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 78  شماره 

صفحات  -

تاریخ انتشار 2013