Wind-Driven Roof Turbines: A Novel Way to Improve Ventilation for TB Infection Control in Health Facilities

نویسندگان

  • Helen Cox
  • Rod Escombe
  • Cheryl McDermid
  • Yolanda Mtshemla
  • Tim Spelman
  • Virginia Azevedo
  • Leslie London
چکیده

OBJECTIVE Tuberculosis transmission in healthcare facilities contributes significantly to the TB epidemic, particularly in high HIV settings. Although improving ventilation may reduce transmission, there is a lack of evidence to support low-cost practical interventions. We assessed the efficacy of wind-driven roof turbines to achieve recommended ventilation rates, compared to current recommended practices for natural ventilation (opening windows), in primary care clinic rooms in Khayelitsha, South Africa. METHODS Room ventilation was assessed (CO₂ gas tracer technique) in 4 rooms where roof turbines and air-intake grates were installed, across three scenarios: turbine, grate and window closed, only window open, and only turbine and grate open, with concurrent wind speed measurement. 332 measurements were conducted over 24 months. FINDINGS For all 4 rooms combined, median air changes per hour (ACH) increased with wind speed quartiles across all scenarios. Higher median ACH were recorded with open roof turbines and grates, compared to open windows across all wind speed quartiles. Ventilation with open turbine and grate exceeded WHO-recommended levels (60 Litres/second/patient) for 95% or more of measurements in 3 of the 4 rooms; 47% in the remaining room, where wind speeds were lower and a smaller diameter turbine was installed. CONCLUSION High room ventilation rates, meeting recommended thresholds, may be achieved using wind-driven roof turbines and grates, even at low wind speeds. Roof turbines and air-intake grates are not easily closed by staff, allowing continued ventilation through colder periods. This simple, low-cost technology represents an important addition to our tools for TB infection control.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

TB/HIV Co-Infection Care in Conflict-Affected Settings: A Mapping of Health Facilities in the Goma Area, Democratic Republic of Congo

Background HIV/AIDS and Tuberculosis (TB) are major contributors to the burden of disease in sub-Saharan Africa. The two diseases have been described as a harmful synergy as they are biologically and epidemiologically linked. Control of TB/HIV co-infection is an integral and most challenging part of both national TB and national HIV control programmes, especially in contexts of instability wher...

متن کامل

Design an optimized model to improve natural ventilation thorough the roof orientation

Natural ventilation is among those effective methods that is useful in hot dry climates. One of its important uses is in the atrium spaces in the office buildings. Although, as a passive solution, it has a significant impact on the reduction of energy consumption, the control of inlet and outflow of air as well as the control of air current temperature has always been a challenge for architects...

متن کامل

GA-Based Optimal LQR Controller to Improve LVRT Capability of DFIG Wind Turbines

Nowadays, the doubly-fed induction generators (DFIGs) based wind turbines (WTs) are the dominant type of WTs connected to grid. Traditionally the back-to-back converters are used to control the DFIGs. In this paper, an Indirect Matrix Converter (IMC) is proposed to control the generator. Compared with back-to-back converters, IMCs have numerous advantages such as: higher level of robustness, re...

متن کامل

Natural Ventilation: Analysis of Indoor Airflow in an Assumed Cubic Building with Opposite Openings by CFD Investigations

The natural ventilation is an easy way to exchange the indoor polluted warm air with outdoor fresh air. The wind power injects outdoor fresh air into the building. A good indoor air current and subsequently a proper exhaust depend on the openings’ conditions and their situations. A serious architectural question is under what conditions of the openings the wind-cross ventilation can be effectiv...

متن کامل

Evaluating the Efficiency of Different Cover Forms of the Large Spans in Flowers and Plant Exhibitions Based on the Natural Ventilation Vystem in a Moderate and Humid Climate

Deciding the roof type with a large ventilation spans for uses in the flower and plant exhibitions that can operate beyond the exhibition space functions as it can provide a desirable climate for the growth of its plants, it can be designed and enhanced according to the geographical site of it. Deciding and designing the roof form can prevent dissipations in energy and assets and develops a con...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 7  شماره 

صفحات  -

تاریخ انتشار 2012