Diagnostics Update of the Taiwan Light Source

نویسندگان

  • C. H. Kuo
  • P. C. Chiu
چکیده

Diagnostics of the 1.5 GeV Taiwan Light Source (TLS) have been continuously upgraded since its operation started in 1993. The BPM electronics of the Taiwan Light Source (TLS) have been upgraded to Libera Brilliance in August 2008 to improve performance and functionality. Orbit feedback has also been migrated to a fast orbit feedback system to enhance orbit stability. Commercial photon BPM electronics were tested recently. A new-generation bunch-by-bunch feedback processor to improve beam stability was tested. Postmortem diagnostic tools were gradually added to clarify reasons for beam trip. These upgrades contributed to improving beam quality and machine availability greatly.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic Supports for Top-up Operation at Tls

The routine top-up operation of Taiwan Light Source (TLS) began in October 2005. The beam stability and integrated flux were drastically improved. Various diagnostics are needed to support the top-up operation. These tools include diagnostics for measuring beam charge and current and injection efficiency, as well as a filling pattern monitor, a tune monitor, and an instability and loss pattern ...

متن کامل

Influences of Device Architectures on Characteristics of Organic Light-Emitting Devices Incorporating Ambipolar Blue-Emitting Ter(9,9-diarylfluorenes)

In this article, we report the studies of various device architectures of organic lightemitting devices (OLEDs) incorporating highly efficient blue-emitting and ambipolar carriertransport ter(9,9-diarylfluorene)s, and their influences on device characteristics. The device structures investigated include single-layer devices and multilayer heterostructure devices employing the terfluorene as one...

متن کامل

Design Status of the Diagnostic System for the Taiwan Photon Source Project

The Taiwan Photon Source (TPS) is a 3 GeV synchrotron light source being built at the campus of NSRRC. Designs of various diagnostics are under way, and will be deployed in the future, to satisfy stringent requirements of TPS for commissioning, top-up injection, and operation. These designs, including beam intensity observation, trajectory and beam positions measurement, destructive profile mea...

متن کامل

A Study on the Establishment of ECFA between Mainland of China and Taiwan

As the chances of a successful conclusion to the Doha Round of trade liberalization under the WTO become increasingly problematic, so the pace of negotiating local free trade agreements (FTAs) is increasing. According to the WTO report, countries in the Asia-Pacific region are “consolidating their drive towards regionalism at an accelerated pace”. After the trade agreements between China an...

متن کامل

A Quick update from the Past to Current Status of Human Pluripotent Stem Cell-derived Hepatocyte culture systems

Pluripotent stem cells (PSCs) may be offered as an unlimited cell source for the hepatocyte generation. The generation of hepatocytes from stem cells in vitro would provide an alternative cell source for applications in drug discovery and cell transplantation. In this review, we discuss different approaches to generate pluripotent stem cell-derived hepatocytes, advantages, limitations for each ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010