Application of a new phased-array ultrasound imaging catheter in the assessment of vascular dimensions. In vivo comparison to cineangiography.

نویسندگان

  • S E Nissen
  • C L Grines
  • J C Gurley
  • K Sublett
  • D Haynie
  • C Diaz
  • D C Booth
  • A N DeMaria
چکیده

Tomographic imaging techniques such as ultrasound can provide important information in the evaluation of vascular anatomy. Recent technical advances have permitted fabrication of a small (1.83 mm), phased-array, intravascular ultrasonic imaging catheter capable of continuous real-time, cross-sectional imaging of blood vessels. We used this imaging catheter to compare intraluminal ultrasound with cineangiography in the measurement of vascular dimensions in animals and to assess the intraobserver and interobserver variability of the technique. Segmental deformation of vessel anatomy was produced by stenoses created with a tissue ligature or by balloon dilation. The mean value for measurements of vessel diameter was 5.6 mm by cineangiography and 5.7 mm by intravascular ultrasound. The correlation between cineangiography and ultrasound was close (r = 0.98). Mean cross-sectional area by angiography was 28.8 mm2 and 29.6 mm2 (r = 0.96) by ultrasound. Percent diameter reduction produced by the stenoses averaged 48.4% by cineangiography and 40.1% by ultrasound, and the two methods correlated closely (r = 0.89). Correlation between cineangiography and ultrasound for vessel diameter and area before balloon dilation was closer (r = 0.92 and 0.88) than after balloon dilation (r = 0.86 and 0.81). This difference reflected an increase in measured vessel eccentricity following balloon dilation. These data demonstrate that intravascular ultrasound is an accurate and reproducible method for measurement of vascular diameter and cross-sectional area in vivo. Intravascular ultrasound is capable of accurately identifying and quantifying segmental deformation of vascular dimensions produced by either stenoses or balloon dilation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

New Phased-Array Ultrasound Imaging Catheter in the Assessment of Vascular Dimensions

uous real-time, cross-sectional imaging of blood vessels. We used this imaging catheter to compare intraluminal ultrasound with cineangiography in the measurement of vascular dimensions in animals and to assess the intraobserver and interobserver variability of the technique. Segmental deformation of vessel anatomy was produced by stenoses created with a tissue ligature or by balloon dilation. ...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

Phased array ultrasonic imaging using an improved beamforming based total focusing method for non destructive test

One of the novel ultrasonic phased array based scanning methods for ultrasonic imaging in non-destructive test is total focusing method (TFM). This method employs maximum available information of the phased array elements and leads to an improved defect detection accuracy compared to conventional scanning methods. Despite its high detection accuracy, TFM behaves weak in distinguishing the real ...

متن کامل

Evaluation of a 99mTc-tricine Vascular Disrupting Agent as an In-vivo Imaging in 4T1 Mouse Breast Tumor Model

Colchicine as a vascular disrupting agent creates microtubule destabilization whichinduces vessel blockage and consequently cell death. Accordingly, colchicines and itsanalogues radiolabeled with 99mTc may have potential for visualization of tumor. In this work,deacetylcolchicine a colchicine analogue was labeled with 99mTc via tricine as a coligandand characterized for its tumor targeting prop...

متن کامل

Evaluation of a 99mTc-tricine Vascular Disrupting Agent as an In-vivo Imaging in 4T1 Mouse Breast Tumor Model

Colchicine as a vascular disrupting agent creates microtubule destabilization whichinduces vessel blockage and consequently cell death. Accordingly, colchicines and itsanalogues radiolabeled with 99mTc may have potential for visualization of tumor. In this work,deacetylcolchicine a colchicine analogue was labeled with 99mTc via tricine as a coligandand characterized for its tumor targeting prop...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 81 2  شماره 

صفحات  -

تاریخ انتشار 1990