Measurement of atherosclerotic carotid plaque size in vivo using high resolution magnetic resonance imaging.
نویسندگان
چکیده
BACKGROUND Current imaging modalities, such as contrast angiography, accurately determine the degree of luminal narrowing but provide no direct information on plaque size. Magnetic resonance imaging (MRI), however, has potential for noninvasively determining arterial wall area (WA). This study was conducted to determine the accuracy of in vivo MRI for measuring the cross-sectional maximum wall area (MaxWA) of atherosclerotic carotid arteries in a group of patients undergoing carotid endarterectomy. METHODS AND RESULTS Fourteen patients scheduled for carotid endarterectomy underwent preoperative carotid MRI using a custom-made phased-array coil. The plaques were excised en bloc and scanned using similar imaging parameters. MaxWA measurements from the ex vivo MRI were used as the reference standard and compared with MaxWA measurements from the corresponding in vivo MR study. Agreement between the in vivo and ex vivo measurement was analyzed using the Bland-Altman method. The paired in vivo and ex vivo MaxWA measurements strongly agreed: the mean difference (in vivo minus ex vivo) in MaxWA was 13.1+/-6.5 mm2 for T1-weighted (T1W) imaging (mean MaxWA in vivo=94.7 mm2, ex vivo=81.6 mm2) and 14.1+/-11.7 mm2 for proton density-weighted (PDW) imaging (mean MaxWA in vivo=93.4 mm2, ex vivo=79.3 mm2). Intraobserver and interobserver variability was small, with intraclass correlation coefficients ranging from 0.90 to 0.98. CONCLUSIONS MRI is highly accurate for in vivo measurement of artery WA in atherosclerotic carotid lesions. This imaging technique has potential application monitoring lesion size in studies examining plaque progression and/or regression.
منابع مشابه
High-resolution intravascular magnetic resonance quantification of atherosclerotic plaque at 3T
BACKGROUND The thickness of fibrous caps (FCT) of atherosclerotic lesions is a critical factor affecting plaque vulnerability to rupture. This study tests whether 3 Tesla high-resolution intravascular cardiovascular magnetic resonance (CMR) employing tiny loopless detectors can identify lesions and accurately measure FCT in human arterial specimens, and whether such an approach is feasible in v...
متن کاملCarotid plaque assessment using fast 3D isotropic resolution black-blood MRI.
Black-blood MRI is a promising tool for carotid atherosclerotic plaque burden assessment and compositional analysis. However, current sequences are limited by large slice thickness. Accuracy of measurement can be improved by moving to isotropic imaging but can be challenging for patient compliance due to long scan times. We present a fast isotropic high spatial resolution (0.7×0.7×0.7 mm3) thre...
متن کاملDirection of Plaque Progression is a Significant Predictor in Plaque Vulnerability: An Evaluation by MRI
Introduction Vascular disease is the leading cause of death and disability in the United States. A great deal of evidence shows that atherosclerotic plaque components are a decisive factor determining plaque vulnerability. The rapid development of high resolution magnetic resonance imaging (MRI) technology has enabled the use of gadolinium-based contrast enhanced post contrast T1-weighted image...
متن کاملClassification of human carotid atherosclerotic lesions with in vivo multicontrast magnetic resonance imaging.
BACKGROUND Recent studies demonstrated that in vivo and ex vivo MRI can characterize the components of the carotid atherosclerotic plaque, such as fibrous tissue, lipid/necrotic core, calcium, hemorrhage, and thrombus. The purpose of this study was to determine whether in vivo high-resolution multicontrast MRI could accurately classify human carotid atherosclerotic plaque according to the Ameri...
متن کاملFeasibility of in vivo measurement of carotid wall shear rate using spiral Fourier velocity encoded MRI.
Arterial wall shear stress is widely believed to influence the formation and growth of atherosclerotic plaque; however, there is currently no gold standard for its in vivo measurement. The use of phase contrast MRI has proved to be challenging due to partial-volume effects and inadequate signal-to-noise ratio at the high spatial resolutions that are required. This work evaluates the use of spir...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 98 24 شماره
صفحات -
تاریخ انتشار 1998