Comparison of blood flow and patency in arterial and vein grafts to basilar artery.

نویسندگان

  • C J Whang
  • J R Mozingo
  • A L Rhoton
چکیده

Blood flow and patency rates obtained by lingual to basilar artery anastomosis were compared with those obtained by saphenous vein bypass graft from the carotid to the basilar artey in two groups of ten dogs. Flow was measured by an electromagnetic technique while blood pressure and blood gases were monitored. Graft patency also was determined by angiography and histological examination. The arterial and venous grafts carried more than enough blood to maintain a normal flow (9.5 ml per minute) through the basilar system of dogs. Immediately after anastomosis, average flow through the vein grafts was 15.5 ml per minute (range 10 to 24 ml per minute). Six weeks later, average flow through the vein graft was 11.5 ml per minute and through the arterial graft 13 ml per minute. With induced hypertension, flow increased in the arterial grafts to an average of 26.2 ml per minute and in the vein grafts 24 ml per minute. Hypercarbia increased arterial graft flow to an average of 27.8 ml per minute and vein graft flow to 23.5 ml per minute. By angiography, graft patency was shown in only 80% of the grafts at one week and in 60% at six weeks postoperatively, even though all grafts were patent by flow and histological determinations. This failure of angiography represents a limitation of the radiographical resolution in millimeter-sized vessels.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the Haemodynamic Parameters of Venous and Arterial Coronary Artery Bypass Conduits.

Dear Editor, Coronary artery bypass grafting (CABG) is an established revascularisation treatment for patients with coronary artery disease (CAD). However, the graft patency rate varies significantly among different bypass graft conduits. Ten years after CABG, more than 90% of the left internal mammary artery (LIMA) grafts are patent1 but the patency rate of saphenous vein grafts (SVGs) ranges ...

متن کامل

Competitive flow and arterial graft a word of caution.

reliable, exclusively in appropriately selected situations. In creation of bypass grafts, durable completeness of revascularization and function of the ITA to the LAD bypass should not be compromised. We would suggest that the balanced bypass flow toward the LAD and the RCA is noticeably important to achieve an entire patency of the Y-graft for three-vessel regions. This study is not conclusive...

متن کامل

A Comparison of Interposition and Femoropopliteal Bypass Grafts in the Management of Popliteal Artery Trauma

Background: Peripheral vascular injury associated with lower limb trauma is a well-known emergency. The experience for the management of popliteal artery trauma have mainly come from managing the traumas of military personnels during Iran-Iraq war. The present study compared the effects of two currently-used surgical techniques in the management of popliteal trauma, namley femoropopliteal bypas...

متن کامل

Comparative patency between intracranial arterial pedicle and vein bypass surgery.

BACKGROUND Long-term patency of extracranial-to-intracranial (EC-IC) vein bypass is poorly understood. OBJECTIVE We report our experience of patency of arterial pedicle grafts and interposition vein grafts for the purpose of EC-IC bypass. METHODS We analyzed 294 consecutive patients who underwent 178 intracranial arterial pedicle bypass procedures and 152 intracranial vein bypass procedures...

متن کامل

Current status of arterial grafts for coronary artery bypass grafting.

For over a decade there has been accumulating evidence that the use of more than a single arterial graft during coronary artery bypass grafting can improve clinical outcomes. However the vast majority of patients in most developed countries still only receive a single arterial conduit even in the presence of multivessel coronary artery disease. This review summarizes the current evidence for th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Stroke

دوره 6 4  شماره 

صفحات  -

تاریخ انتشار 1975