In vivo study of corneal responses to increased intraocular pressure loading

نویسندگان

  • Ahmed Elsheikh
  • Charles W. McMonnies
  • Charles Whitford
  • Gavin C. Boneham
چکیده

BACKGROUND The cornea is responsible for two-thirds of the eye's refractive power which is a function of the shape and refractive index. The aim of this present study is to examine human eyes in vivo for corneal shape changes in response to short-term elevation in intraocular pressure. METHODS Videokeratographic and tonometric assessments at baseline were compared with the same assessments when intraocular pressure was elevated to approximately double (199 ± 22 %) the baseline levels using ophthalmodynamometer applanation of the sclera. Composite maps of the cornea and limbus were created by combining topographical assessments for central, nasal, temporal, inferior and superior fixation. Numerical finite-element simulations were custom built for each subject and the stiffness distribution across corneal surface modified to achieve matches between simulated and experimental data. RESULTS The stiffness distributions required to achieve simulation-experimental matches showed a consistent trend with the 2.5 mm annulus bounded by the limbus showing a mean stiffness reduction of 47.3 ± 10.8 % compared with the central cornea (P = 0.001). CONCLUSIONS Corneal structure appears to provide the central cornea with a greater stiffness compared with the peripheral cornea and associated greater tolerance to elevation in intraocular pressure, consistent with the need for stable corneal refraction and vision. The method adopted to examine corneal biomechanical performance in vivo may have applications in additional studies.

منابع مشابه

Studies on Corneal Permeation and Oculo-Hypotensive Effect of Benazepril in Chronic and Acute Models of Glaucoma

ABSTRACT The present study was carried out to investigate the effect of benazepril on corneal permeation in goat cornea and its effect on experimentally induced acute and chronic glaucoma in rabbits. Acute glaucoma was produced by i.v. infusion of 5% glucose (15ml / Kg) in rabbits, whereas chronic glaucoma was induced by injection of alpha-chymotrypsin into posterior chamber of rabbit eye. We s...

متن کامل

Intraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea

Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...

متن کامل

Ocular Dorzolamide Nanoliposomes for Prolonged IOP Reduction: in-vitro and in-vivo Evaluation in Rabbits

Dorzolamide ophthalmic drop is one of the most common glaucoma medications but it has a short residence time in the eye. The aim of this study is to develop ocular dorzolamide HCl nanoliposomes (DRZ – nanoliposomes) and to evaluate their potential use for the treatment of ocular hypertension. Nanoliposomes were prepared using Reverse-phase evaporation vesicle (REV) and thin layer hydration (TLH...

متن کامل

Ocular Dorzolamide Nanoliposomes for Prolonged IOP Reduction: in-vitro and in-vivo Evaluation in Rabbits

Dorzolamide ophthalmic drop is one of the most common glaucoma medications but it has a short residence time in the eye. The aim of this study is to develop ocular dorzolamide HCl nanoliposomes (DRZ – nanoliposomes) and to evaluate their potential use for the treatment of ocular hypertension. Nanoliposomes were prepared using Reverse-phase evaporation vesicle (REV) and thin layer hydration (TLH...

متن کامل

بررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن

To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

متن کامل
عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015