Accuracy of pressure and flow capacities of four arthroscopic fluid management systems.
نویسندگان
چکیده
PURPOSE The present study was conducted to evaluate 4 different fluid delivery systems: Arthrex AR-6450, Stryker 1.5L High Flow Pump, Arthro FMS 4, and Acufex InteliJet. Their flow and pressure capacity, as specified by the manufacturer, and their accuracy, as measured in a standardized fashion, were compared with directly measured pressure values. TYPE OF STUDY Experimental study. METHODS Two experiments were performed: (1) the achieved pressure was measured with the pressure sensor within a ball and compared with the preset pressure values. The pressure was increased constantly while the flow was kept constant. (2) maximum flow per minute was tested using a beaker and a stopwatch. RESULTS The highest measured pressures for the Arthrex and the Stryker pumps were 115 mm Hg (46% of published maximum pressure) and 113 mm Hg (57% of published maximum pressure), respectively. The highest measured pressures for the Arthro FMS 4 and the InteliJet pumps were 251 mm Hg (101% of published pressure) and 132 mm Hg (88% of published maximum pressure), respectively. The maximal flow values for the Arthrex and Stryker pumps were 900 mL/min (56.3%) and 675 mL/min (48%), respectively. The Arthro FMS 4 and InteliJet pumps reached a maximal flow of 450 mL/min (56%) and 1,250 mL/min (62.5%). CONCLUSIONS In the simpler pumps (Arthrex AR-6450 and Stryker 1.5L High Flow Pump), the pressure on the display must be set to higher values compared with the outflow-controlling pumps (Arthro FMS 4 and InteliJet) to achieve the same intra-articular pressure. All pumps were able to maintain a pressure of 60 mm Hg very accurately. Therefore, a surgeon can trust all of the pumps when the pressure is set below 60 mm Hg.
منابع مشابه
Flow Variables Prediction Using Experimental, Computational Fluid Dynamic and Artificial Neural Network Models in a Sharp Bend
Bend existence induces changes in the flow pattern, velocity profiles and water surface. In the present study, based on experimental data, first three-dimensional computational fluid dynamic (CFD) model is simulated by using Fluent two-phase (water + air) as the free surface and the volume of fluid method, to predict the two significant variables (velocity and channel bed pressure) in 90º sharp...
متن کاملThe Influence of the Pipe’s Material and the Mass Flow Rate on the Pressure Drop and Velocity Variation During Pneumatic Conveying of Wheat Using Computational Fluid Dynamics
According to flexibility of pneumatic conveying systems with respect to other types of transmission systems, this system has wide application in industry and agriculture processes. One important application of this system is in the loading and unloading tankers and powdery bulk materials such as trucks carrying cement, plaster and sand. Conveying efficiency is associated with pressure, which in...
متن کاملThe Influence of the Pipe’s Material and the Mass Flow Rate on the Pressure Drop and Velocity Variation During Pneumatic Conveying of Wheat Using Computational Fluid Dynamics
According to flexibility of pneumatic conveying systems with respect to other types of transmission systems, this system has wide application in industry and agriculture processes. One important application of this system is in the loading and unloading tankers and powdery bulk materials such as trucks carrying cement, plaster and sand. Conveying efficiency is associated with pressure, which in...
متن کاملInvestigation of Fluid-structure Interaction by Explicit Central Finite Difference Methods
Fluid-structure interaction (FSI) occurs when the dynamic water hammer forces; cause vibrations in the pipe wall. FSI in pipe systems due to Poisson and junction coupling has been the center of attention in recent years. It causes fluctuations in pressure heads and vibrations in the pipe wall. The governing equations of this phenomenon include a system of first order hyperbolic partial differen...
متن کاملVibrational characteristics of a spinning thermally affected cylindrical shell conveying viscous fluid flow carrying spring-mass systems
In this article, the vibrational behavior of a spinning cylindrical thick shell carrying spring- mass systems and conveying viscos fluid flow under various temperature distributions is investigated. This structure rotates about axial direction and the formulations include the coriolis and centrifugal effects. In addition, this system is conveying viscous fluid, and the related force is calculat...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
دوره 17 7 شماره
صفحات -
تاریخ انتشار 2001