Comparison of Various Root Planing Instruments: Hand and Ultrasonic—Standard Smooth and Diamond Coated: An in vivo Study

نویسنده

  • Sushama R Galgali
چکیده

Aim and objective: This study was conducted to evaluate and compare the effectiveness of various root planing instruments, namely the curette, standard smooth ultrasonic tip and diamond coated ultrasonic tip under conditions of nonsurgical root debridement. Materials and methods: A total of 20 incisors from 14 patients, with a pocket depth of 5 to 10 mm, indicated for extraction were selected for the study. Teeth selected were randomly assigned to one of the two groups, experimental group A and experimental group B. The proximal surfaces of teeth in experimental group A was instrumented with either Gracey curette or standard smooth ultrasonic tip and in experimental group B with either Gracey curette or diamond coated ultrasonic tip, randomly. Teeth were extracted without injuring the experimental area. The surface area under treatment was photographed at 10X and the percentage of residual calculus was evaluated. Teeth were processed for viewing under scanning electron microscope. Photomicrographs were graded for degree of cleanliness, Remaining Calculus Index (RCI) and Roughness and Loss of Tooth Substance Index (RLTSI) by an independent examiner. Results: Percentage of residual calculus as evaluated using stereomicroscope did not show any statistical significance within the groups and among all the three instruments. Scanning electron microscopic assessment for the degree of cleanliness showed better cleanliness for curette compared to standard smooth ultrasonic tip. Remaining calculus was significantly higher for standard smooth ultrasonic tip compared to curette. Diamond coated ultrasonic tip showed greater roughness and loss of tooth substance. Conclusion: Within the limits of this in vivo study, diamond coated ultrasonic tip removed a greater amount of root surface and created a rougher surface compared to the curette and standard smooth ultrasonic tip. The amount of root surface removed with diamond coated ultrasonic inserts suggests that they should be used with caution.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A comparative scanning electron microscopy study between hand instrument, ultrasonic scaling and erbium doped:Yttirum aluminum garnet laser on root surface: A morphological and thermal analysis

BACKGROUND AND OBJECTIVES Scaling and root planing is one of the most commonly used procedures for the treatment of periodontal diseases. Removal of calculus using conventional hand instruments is incomplete and rather time consuming. In search of more efficient and less difficult instrumentation, investigators have proposed lasers as an alternative or as adjuncts to scaling and root planing. H...

متن کامل

Comparative in Vitrostudy of Root Roughness after Instrumentation with Ultrasonic and Diamond Tip Sonic Scaler

OBJECTIVE The purpose of this study was to evaluate the root surface roughness after instrumentation with hand curette and diamond-coated sonic and universal ultrasonic tips. MATERIALS AND METHODS Forty root surfaces of human teeth were randomly assigned to four treatment groups: control group (without instrumentation), curette instrumentation, ultrasonic instrumentation with universal tip an...

متن کامل

Root Surface Roughness After Scaling and Root Planing with Er:YAG Laser Compared to Hand and Ultrasonic Instruments by Profilometry

OBJECTIVES Scaling and root planing (SRP) is one of the most commonly used procedures during periodontal treatment. The aim of this study was to evaluate the root surface roughness after SRP with erbium: yttrium aluminum garnet (Er:YAG) laser compared to ultrasonic and hand instruments. MATERIALS AND METHODS In this experimental study, 56 extracted sound single-rooted teeth with moderate leve...

متن کامل

Comparison of the effects of various periodontal rotary instruments on surface characteristics of root surface.

The efficacy of scaling and root planing using various periodontal rotary instruments was examined. Eighty extracted human teeth with a history of periodontal disease were divided into four groups of 20 and subjected to one of the following procedures: Use of 1) a Root Burnisher, 2) a Perio Planing Bur (both rotating instruments for contra angle handpieces), 3) a Tooth Planing Bur (rotating ins...

متن کامل

A comparative study of the cleaning effect of various ultrasonic cleaners on ‎new, unused endodontic instruments

BACKGROUND AND AIM: This study was carried out to compare three different ultrasonic cleaner devices in the cleaning process of endodontic instruments by scanning electron microscope (SEM). METHODS: In this study, 120 unused brand new hand and rotary instruments were examined after removing from the sealed package. The instruments were randomly divided into six groups of 20 rotary or hand files...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2011