Measuring Claw Conformation in Cattle: Assessing the Agreement between Manual and Digital Measurement
نویسندگان
چکیده
Five measurements of claw conformation (toe angle, claw height, claw width, toe length and abaxial groove length) taken directly from the hoof were compared with the measurements taken from digital images of the same claws. Concordance correlation coefficients and limits-of-agreement analysis showed that, for four of the five measures (claw height, claw width, toe length and abaxial groove length), agreement was too poor for digital and manual measures to be used interchangeably. For all four of these measures, Liao's modified concordance correlation coefficient (mCCC) was ≤0.4, indicating poor concordance despite Pearson's correlation being >0.6 in all cases. The worst concordance was seen for toe length (mCCC = 0.13). Limits-of-agreement analysis showed that, for all four measures, there was a large variation in the difference between the manual and digital methods, even when the effect of mean on difference was accounted for, with the 95% limits-of-agreement for the four measures being further away from the mean difference than 10% of the mean in all four cases. The only one of the five measures with an acceptable concordance between digital and manual measurement was toe angle (mCCC = 0.81). Nevertheless, the limits-of-agreement analysis showed that there was a systematic bias with, on average, the manual measure of toe angle, being 2.1° smaller than the digital. The 95% limits-of-agreement for toe angle were ±3.4°, probably at the upper limit of what is acceptable. However, the lack of data on the variability of individual measurements of claw conformation means that it is unclear how this variability compares to measurement of toe angle in the same animal using the same or a different manual technique.
منابع مشابه
Diagnostic Accuracy of Digitized Images Using Different Resolution Settings of Digital Camera in Detection of Proximal Caries
Objective: When none of digital systems and scanners is accessible and it is essential to have digitized images of conventional radiographs, digital cameras can be used. The Aim of this study was to investigate whether digital images obtained by different resolutions of a digital camera are matched to the original radiographs in evaluation of caries. Methods: In this diagnostic accuracy in v...
متن کاملMeasuring the deposited energy from a non-ionizing laser beam in water by digital holographic interferometry
Digital Holographic interferometry is a powerful and widely used optical technique for accurate measurement of variations in physical quantities such as density, refractive index, and etc. In this study, an experimental digital holographic interferometry setup was designed and used to measure the amount of energy changes induced by absorption of radiation from a non-ionizing infrared laser beam...
متن کاملFootpad horn hypertrophy and vertical fissure accompanied by white line disease 2 in case of concurrent deep digital sepsis in a culling cow
A5.2 year-old Holstein cow was presented with lameness andabnormal weight bearing in a slaughterhouse. Widening of theperiople and swelling of the heel area in the lateral claw was morepermanent than the medial claw. Vertical fissure (VF) involvingthe coronary band to the middle of the dorsal wall of the medialhind claw was observed. It was also extended to the bearingsurface in the inner surfa...
متن کاملاعتبار و تکرارپذیری Dual Digital Inclinometer در اندازه گیری زاویه کایفوز پشتی در زنان بالای 45 سال
Objective: Accurate measurement of thoracic kyphosis has high value in the evaluation of patients with spinal kyphosis and in assessing the effectiveness of different treatment methods. Recently, Dual Digital Inclinometer (DDI) has introduced as a non-invasive tool that can measure the kyphosis angle. According to available information there is only one published study regarding the validity an...
متن کاملComparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects
Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects. Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...
متن کامل