Comparison of respiratory triggering and gating techniques for the removal of respiratory artifacts in MR imaging.

نویسندگان

  • C E Lewis
  • F S Prato
  • D J Drost
  • R L Nicholson
چکیده

Respiratory movement degrades magnetic resonance (MR) images of the chest and abdomen by increasing noise through the production of "ghost" artifacts and by decreasing edge sharpness in moving structures. Respiratory gating, which limits data acquisition to end-expiration, is successful in restoring edge sharpness and reducing ghosts but increases imaging time two to three times, which limits its use to sequences with short repetition times (TRs). To overcome this limitation, an alternative technique, respiratory triggering, was developed, which triggers the acquisition of an MR section at a fixed point on the respiratory cycle. This technique restores edge sharpness and reduces ghosts, but unlike gating, it can be used to produce an image at any phase of the respiratory cycle. Triggering requires long TRs since the TR is limited to the respiratory period (TP) or one-half of TP, depending on whether the same section is triggered once or twice during a single respiratory cycle. Gating and triggering were evaluated and compared for single-section and multi-section imaging of both volunteers and patients. The authors conclude that when a chest or abdominal survey is required, triggering takes less time than gating if TRs are required that exceed one-fifth of TP.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

Highly efficient respiratory gating in whole heart MR employing non-rigid retrospective motion correction

Introduction: Three-dimensional whole heart imaging becomes the method of choice in various cardiac applications [1] as it avoids extensive planning of imaging slices and allows reconstructing arbitrary slice orientations. The drawback of the method is a relatively long scan time (on the order of several minutes) which requires motion compensation to suppress motion artifacts. A typical approac...

متن کامل

The Efficiency of Respiratory-gated 18F-FDG PET/CT in Lung Adenocarcinoma: Amplitude-gating Versus Phase-gating Methods

Objective(s): In positron emission tomography (PET) studies, thoracic movement under free-breathing conditions is a cause of image degradation. Respiratory gating (RG) is commonly used to solve this problem. Two different methods, i.e., phase-gating (PG) and amplitude-gating (AG) PET, are available for respiratory gating. It is important to know the strengths and weaknesses of both methods when...

متن کامل

Reducing the respiratory motion artifacts in PET cardiology: A simulation study

  Introduction: There are several technical features that make PET an ideal device for the noninvasive evaluation of cardiac physiology. Organ motion due to respiration is a major challenge in diagnostic imaging, especially in cardiac PET imaging. These motions reduce image quality by spreading the radiotracer activity over an increased volume, distorting apparent les...

متن کامل

Combined Electrocardiography- and Respiratory-Triggered CT of the Lung to Reduce Respiratory Misregistration Artifacts between Imaging Slabs in Free-Breathing Children: Initial Experience

OBJECTIVE Cardiac and respiratory motion artifacts degrade the image quality of lung CT in free-breathing children. The aim of this study was to evaluate the effect of combined electrocardiography (ECG) and respiratory triggering on respiratory misregistration artifacts on lung CT in free-breathing children. MATERIALS AND METHODS In total, 15 children (median age 19 months, range 6 months-8 y...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiology

دوره 160 3  شماره 

صفحات  -

تاریخ انتشار 1986