Additional Evaluation of the Point-of-Contact Circulating Cathodic Antigen Assay for Schistosoma mansoni Infection

نویسندگان

  • Pauline N. M. Mwinzi
  • Nupur Kittur
  • Elizabeth Ochola
  • Philip J. Cooper
  • Carl H. Campbell
  • Charles H. King
  • Daniel G. Colley
چکیده

Studies of the urine-based point-of-contact cathodic circulating antigen test (POC-CCA) in Schistosoma mansoni-endemic settings in Africa indicate it has good sensitivity in detecting infections, but in areas of low prevalence, the POC-CCA can be positive for persons who are egg-negative by Kato-Katz stool assays. We examined the POC-CCA assay for: (a) batch-to-batch stability; (b) intra-reader and inter-reader variability; (c) day-to-day variability compared to Kato-Katz stool assays, and (d) to see if praziquantel (PZQ) treatment converted Kato-Katz-negative/POC-CCA positive individuals to POC-CCA negativity. We found essentially no batch-to-batch variation, negligible intra-reader variability (2%), and substantial agreement for inter-reader reliability. Some day-to-day variation was observed over 5 days of urine collection, but less than the variation in Kato-Katz stool assays over 3 days. To evaluate the effect of treatment on Kato-Katz(-)/POC-CCA(+) children, 149 children in an area of 10-15% prevalence who were Kato-Katz(-) based on 3 stool samples but POC-CCA(+) were enrolled. Seven days after treatment (PZQ 40 mg/kg) samples were again collected and tested. Almost half (47%) POC-CCA positive children turned negative. Those still POC-CCA positive received a second treatment, and 34% of them turned POC-CCA negative upon this second treatment. Most who remained POC-CCA positive shifted each time to a "lesser" POC-CCA "level of positivity." The data suggest that most Kato-Katz-negative/POC-CCA positive individuals harbor low-intensity infections, and each treatment kills all or some of their adult worms. The data also suggest that when evaluated by a more sensitive assay, the effective cure rates for PZQ are significantly less than those inferred from fecal testing. These findings have public health significance for the mapping and monitoring of Schistosoma infections and in planning the transition from schistosomiasis morbidity control to elimination of transmission.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Schistosoma mansoni Prevalence and Intensity of Infection, as Determined by the Circulating Cathodic Antigen Urine Assay or by the Kato-Katz Fecal Assay: A Systematic Review

The relationship between results from Kato-Katz (KK) fecal microscopy and urine-based point-of-care circulating cathodic antigen (POC-CCA) assays for Schistosoma mansoni infection remains a critical issue. This systematic literature review of 25 published papers compares prevalence of S. mansoni infection by KK with that by the POC-CCA assay. Nineteen published studies met our inclusion criteri...

متن کامل

The use of circulating cathodic antigen rapid test and serology for diagnosis of active Schistosoma mansoni infection in migrants in Italy, a non-endemic country: a cross sectional study

Diagnosis of schistosomiasis in migrants coming from endemic areas can be difficult, especially in asymptomatic subjects. Light-intensity disease, in fact, may be missed due to the low sensitivity of the stool microscopy and serologic testing cannot distinguish between a resolved infection and an active infection in patients who have been infected and treated in the past, because specific antib...

متن کامل

New Approaches with Different Types of Circulating Cathodic Antigen for the Diagnosis of Patients with Low Schistosoma mansoni Load

BACKGROUND Schistosomiasis mansoni is a debilitating and sometimes fatal disease. Accurate diagnosis plays a key role in patient management and infection control. However, currently available parasitological methods are laborious and lack sensitivity. The selection of target antigen candidates has turned out to be a promising tool for the development of more sensitive diagnostic methods. In our...

متن کامل

A Five-Country Evaluation of a Point-of-Care Circulating Cathodic Antigen Urine Assay for the Prevalence of Schistosoma mansoni

We evaluated a commercial point-of-care circulating cathodic antigen (POC-CCA) test for assessing Schistosoma mansoni infection prevalence in areas at risk. Overall, 4,405 school-age children in Cameroon, Côte d'Ivoire, Ethiopia, Kenya, and Uganda provided urine for POC-CCA testing and stool for Kato-Katz assays. By latent class analysis, one POC-CCA test was more sensitive (86% versus 62%) but...

متن کامل

Day-to-day fluctuation of schistosome circulating antigen levels in serum and urine of humans infected with Schistosoma mansoni in Burundi.

Day-to-day fluctuations of both circulating anodic antigen (CAA) and circulating cathodic antigen (CCA) in serum and urine were examined simultaneously in a group of Schistosoma mansoni-infected individuals from Burundi and compared with each other and with fecal egg count fluctuations. Significant correlations were found between fecal egg counts and circulating antigens (CAA and CCA) and betwe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 3  شماره 

صفحات  -

تاریخ انتشار 2015