Physiological loading of isolated mammalian cardiac muscle.
نویسندگان
چکیده
Cat papillary muscles were subjected to a complex loading function resulting from an analysis of the heart as a pump. The papillary muscle was assumed to be a hypothetical bundle of circumferential muscle fibers in the wall of a simplified cylindrical ventricle. The loading included inertial, resistive, and capacitive components of the cardiovascular system. Changes of ventricular dimensions were taken into account by application of a Laplace relationship. When this complex dynamic loading function was imposed on a shortening muscle by means of an electromagnetic feedback system, the developed force continuously changed with time. The time course of this changing force corresponded to the time course of calculated stress in the intact ejecting heart. Directly displayed force-velocity loops also were similar to loops obtained for the intact heart. Loads proportional to velocity of shortening (damping), acceleration of shortening (inertia), and to the square of shortening velocity (Bernoulli) were investigated separately. Cardiac muscle appeared rather insensitive to inertial loads, and the contribution of inertial loads in the early phase of a contraction under physiological pump loading was minimal. Moreover, during all these dynamic loadings, as long as loading was dynamically increasing or decreasing, velocity of shortening was respectively lower or higher at any muscle length and total load, when compared to velocity at the same length and load under static (constant preload and afterload only) loading.
منابع مشابه
A novel isolated dual perfusion/superfusion heart model for physiological and pharmacological evaluation of mammalian heart preparations
Abstract Introduction: Isolated perfused heart models such as perfusion and superfusion are commonly used for mammalian heart research. However, there are several fundamental limitations in the current techniques. In perfusion model, a suitable cannula is connected to the aorta and the perfusion is retrogradely performed. But, electrode displacement is a potential unwanted event resulted fr...
متن کاملMyoglobin facilitated oxygen diffusion maintains mechanical function of mammalian cardiac muscle.
Myoglobin, an intracellular iron containing protein that binds oxygen reversibly, has been shown in model systems to facilitate the diffusion of oxygen and thereby maintain the mechanical function of exercising canine skeletal muscle and of hypoxic benthic fish hearts. Since no such role has yet been established for mammalian cardiac muscle small diameter (less than or equal to 0.70 mm) isolate...
متن کاملPhysiological loading of isolated feline cardiac muscle. The interaction between muscle contraction and vascular impedance in the production of pressure and flow waves.
Isolated cat papillary muscle preparations were assumed to contract in the wall of a hypothetical cylindrical model of the left ventricle ejecting into a vascular impedance. Using analogcomputing techniques, a feedback system was created between shortening, velocity of shortening, and the load on the muscle. This feedback function could be modulated by altering the resistance and capacitance co...
متن کاملLoad-insensitive relaxation caused by hypoxia in mammalian cardiac muscle.
The relaxation of isolated cardiac muscles from mammals was recently shown to be sensitive to the loading conditions because the time course of relaxation could be changed by changing the load. This effect apparently is related to the amount and functional status of the sarcoplasmic reticulum. The purpose of this study was to determine whether hypoxia affected the load sensitivity of papillary ...
متن کاملVarying Mechanical Loads
or intact muscle. End-systolic pressure-volume relations of frog hearts have been found to be load dependent, whereas those of the mammal are relatively load independent. On the other hand, myocardial relaxation as studied at the muscle level is load independent in the frog but markedly load dependent in the mammal. Interpretation of these studies is complicated because of the unknown contribut...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation research
دوره 39 1 شماره
صفحات -
تاریخ انتشار 1976