Bipolar atrial sensing thresholds in sinus rhythm and atrial tachyarrhythmias. A comparative analysis in patients with DDDR pacemakers.
نویسندگان
چکیده
UNLABELLED Automatic mode switching (AMS) function in dual chamber pacemakers depends on adequate detection of atrial tachyarrhythmias. There are few data on showing how intra-operative atrial signal amplititude during sinus rhythm can predict atrial tachyarrhythmias after pacemaker implantation. In 43 patients undergoing DDDR pacemaker implantation and atrioventricular nodal ablation for the treatment of drug-refractory paroxysmal atrial fibrillation, atrial sensing thresholds during sinus rhythm and during induced atrial tachyarrhythmias (24-48 h after device implantation) were analysed. Five different DDDR pacemaker systems were implanted (Chorus 7034, Ela Medical n = 13; Meta DDDR 1254, Telectronics Pacing Systems n = 12; Vigor DR 1230, Guidant n = 6; Trilogy DR 2364, Pacesetter, n = 2; Kappa DR 401, Medtronic USA n = 10). Every patient received a steroid-eluting, screwing, bipolar atrial lead (Medtronic, Capsure-Fix 4068). The mean P wave amplitude during implantation was 3.91 +/- 1.14 mV. The mean atrial sensing threshold during sinus rhythm and during all modes of induced atrial tachyarrhythmias was 3.35 +/- 1.0 mV, and 1.52 +/- 0.92 mV, respectively (P < 0.001). Atrial fibrillation was induced in 36 patients. The mean sensing threshold during sinus rhythm in this patient group was 3.39 +/- 1.01 mV, the mean sensing threshold during atrial fibrillation was 1.27 +/- 0.56 mV, reflecting a 63% reduction of sensing threshold compared with sinus rhythm (P < 0.001). Atrial flutter was induced in seven patients. The mean sensing threshold during sinus rhythm was 2.92 +/- 1.19 mV, the mean sensing threshold during atrial flutter was 2.79 +/- 1.26 mV, reflecting a reduction of 5% (ns) compared with sinus rhythm. Atrial sensing thresholds during sinus rhythm were significantly correlated with sensing thresholds during atrial tachyarrhythmias (r = 0.44; P < 0.002), but there were significant variations in intra-individual results. The reduction of atrial sensing thresholds between sinus rhythm and induced atrial tachyarrhythmias ranged from 30% to 82%. CONCLUSION Bipolar atrial sensing thresholds during sinus rhythm are correlated with sensing thresholds during atrial tachyarrhythmias, but there is a large degree of variance in individual patients. A 4:1 to 5:1 atrial sensing safety margin based on sensing threshold during sinus rhythm is a predictor for adequate postoperative detection of atrial tachyarrhythmias and the function of AMS devices.
منابع مشابه
Double-counting of intracardiac electrogram during biatrial pacing.
BACKGROUND Biatrial pacing has a significant problem with memory function that misinterprets normal sinus rhythm as atrial tachyarrhythmias and in addition estimation of the atrial pacing thresholds (biatrial and uniatrial pacing thresholds) is sometimes difficult because of small P waves. METHODS AND RESULTS The intracardiac electrograms recorded by a pacemaker in 10 patients (age, 66.7+/-10...
متن کاملAccuracy of mode switch algorithms for detection of atrial tachyarrhythmias.
INTRODUCTION In patients with permanent pacemakers, mode switching events often are interpreted as surrogate markers for atrial tachyarrhythmias. The aim of this study was to determine the accuracy of automatic mode switching algorithms in patients with permanent pacemakers for the diagnosis of atrial tachyarrhythmias. METHODS AND RESULTS Forty patients with tachycardia-bradycardia syndrome a...
متن کاملAtrial antitachycardia pacing and managed ventricular pacing in bradycardia patients with paroxysmal or persistent atrial tachyarrhythmias: the MINERVA randomized multicentre international trial
AIMS Atrial fibrillation (AF) is a common comorbidity in bradycardia patients. Advanced pacemakers feature atrial preventive pacing and atrial antitachycardia pacing (DDDRP) and managed ventricular pacing (MVP), which minimizes unnecessary right ventricular pacing. We evaluated whether DDDRP and MVP might reduce mortality, morbidity, or progression to permanent AF when compared with standard du...
متن کاملAtrial High Rate Episodes Detected by Pacemaker Diagnostics Predict Death and Stroke
Background—Some current pacing systems can automatically detect and record atrial tachyarrhythmias that may be asymptomatic. We prospectively studied a 312-patient (pt) subgroup of MOST (MOde Selection Trial), a 2010-patient, 6-year randomized trial of DDDR versus VVIR pacing in sinus node dysfunction (SND). The purpose of the study was to correlate atrial high rate events (AHREs) detected by p...
متن کاملDemonstration of a widely distributed atrial pacemaker complex in the human heart.
Atrial depolarization was analyzed in 14 patients with the Wolff-Parkinson-White syndrome undergoing surgery to ablate accessory atrioventricular pathways associated with tachyarrhythmias. Bipolar potentials were recorded simultaneously from 156 atrial epicardial electrodes arranged in three templates to fit the anterior and posterior aspects of both atria. Spontaneous or sinus rhythms were rec...