Quantifying effects of retinal illuminance on frequency doubling perimetry.

نویسندگان

  • William H Swanson
  • Mitchell W Dul
  • Susan E Fischer
چکیده

PURPOSE To measure and quantify effects of variation in retinal illuminance on frequency doubling technology (FDT) perimetry. METHODS A Zeiss-Humphrey/Welch Allyn FDT perimeter was used with the threshold N-30 strategy. Study 1, quantifying adaptation: 11 eyes of 11 subjects (24-46 years old) were tested with natural pupils, and then retested after stable pupillary dilation with neutral density filters of 0.0, 0.6, 1.2, and 1.6 log unit in front of the subject's eye. Study 2, predicting effect of reduced illuminance: 17 eyes of 17 subjects (26-61 years old) were tested with natural pupils, and then retested after stable pupillary miosis (assessed with an infrared camera). A quantitative adaptation model was fit to results of Study 1; the mean adaptation parameter was used to predict change in Study 2. RESULTS Study 1: Mean defect (MD) decreased by 10 dB over a 1.6 log unit range of retinal illuminances; model fits for all subjects had r2> 95%. Study 2: Change in MD (DeltaMD) ranged from -7.3 dB to +0.8 dB. The mean adaptation parameter from Study 1 accounted for 69% of the variance in DeltaMD (P <0.0005), and accuracy of the model was independent of the magnitude of DeltaMD (r2< 1%, P >0.75). CONCLUSIONS The results confirmed previous findings that FDT perimetry can be dramatically affected by variations in retinal illuminance. Application of a quantitative adaptation model provided guidelines for estimating effects of pupil diameter and lens density on FDT perimetry.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrobulbar blood flow and visual field alterations after acute ethanol ingestion

BACKGROUND The purpose of this study was to test the effect of ethyl alcohol on the koniocellular and magnocellular pathway of visual function and to investigate the relationship between such visual field changes and retrobulbar blood flow in healthy subjects. METHODS In 12 healthy subjects (mean age 32 ± 4 years), color Doppler imaging, short-wavelength automated perimetry, and frequency dou...

متن کامل

A Comparison of the Effects of Neutral Density Filters and Diffusing Filters on Motion Detection Perimetry, White-on-white Perimetry and Frequency Doubling Perimetry

Background: Motion detection perimetry and frequency doubling perimetry are methods that have been developed with the goal of detecting glaucomatous field defects earlier than conventional white-on-white perimetry. It is well recognized that the development of cataract and pupillary constriction can significantly influence perimetric thresholds when screening for, or following the progression o...

متن کامل

Effect of decreased retinal illumination on frequency doubling technology.

PURPOSE To investigate the effect of changes in retinal illumination on Frequency Doubling Technology (FDT). METHODS Five eyes, of 5 adults who were free from identifiable ocular pathology, were examined using the Snellen chart and the Pelli-Robson chart, conventional automated perimetry, and the full threshold N-30 program of FDT. Each test was performed with and without a 0.9, 1.5, or 2.4 l...

متن کامل

Effect of brimonidine on retinal vascular autoregulation and short-term visual function in normal tension glaucoma.

PURPOSE To assess whether brimonidine 0.15% alters retinal vascular autoregulation and short-term visual function in normal tension glaucoma patients who demonstrate retinal vascular dysregulation. DESIGN Nonrandomized clinical trial. METHODS In this prospective study, 46 normal tension glaucoma patients not previously treated with brimonidine underwent retinal vascular autoregulation testi...

متن کامل

Frequency-doubling technology perimetry for detection of the development of visual field defects in glaucoma suspect eyes: a prospective study.

IMPORTANCE While standard automated perimetry (SAP) remains the reference standard for evaluation of visual field (VF) defects in glaucoma, this study demonstrates that frequency-doubling technology (FDT) perimetry is effective in monitoring visual field progression and may detect the onset of visual field defects earlier than SAP. OBJECTIVES To compare detection of the development of VF defe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 46 1  شماره 

صفحات  -

تاریخ انتشار 2005