Failure of rapid agglutination methods to detect oxacillin-resistant Staphylococcus aureus.
نویسندگان
چکیده
Although a latex agglutination test (StaphAurex) and a hemagglutination test (Staphyloslide) correctly identified all strains of Staphylococcus aureus that were susceptible or had intermediate susceptibility to oxacillin, 17 of 73 (23%) and 18 of 73 (25%) strains of oxacillin-resistant S. aureus were not identified by StaphAurex and Staphyloslide, respectively. All strains not detected were resistant to trimethoprim-sulfamethoxazole and rifampin.
منابع مشابه
Staphylococcus aureus strains which are not identified by rapid agglutination methods are of capsular serotype 5.
A total of 183 recent Staphylococcus aureus clinical isolates were tested with three commercially available rapid agglutination methods. The capsular polysaccharide type and resistance to oxacillin of these isolates were also determined. Seven isolates were not identified correctly by agglutination methods. All isolates not identified by the rapid methods were of capsular serotype 5, and of the...
متن کاملComparison of phenotypic versus genotypic methods in the detection of methicillin resistance in Staphylococcus aureus.
BACKGROUND & OBJECTIVE Conventional methods to detect methicillin resistance in Staphylococcus aureus are inadequate as expression of resistance is subject to environmental and conditional expression of PBP2a antigen. The objective of the present study was to determine methicillin resistance in S. aureus by conventional susceptibility (oxacillin disc diffusion and oxacillin MIC) and molecular m...
متن کاملPerformance of eight methods, including two new rapid methods, for detection of oxacillin resistance in a challenge set of Staphylococcus aureus organisms.
Using a set of 55 Staphylococcus aureus challenge organisms, we evaluated six routine methods (broth microdilution, disk diffusion, oxacillin agar screen, MicroScan conventional panels, MicroScan rapid panels, and Vitek cards) currently used in many clinical laboratories and two new rapid methods, Velogene and the MRSA-Screen, that require less than a day to determine the susceptibility of S. a...
متن کاملEvaluation of three rapid methods for detection of methicillin resistance in Staphylococcus aureus.
The probe-based Velogene Rapid MRSA Identification Assay (ID Biomedical Corp., Vancouver, British Columbia, Canada) and the latex agglutination MRSA-Screen (Denka Seiken Co., Tokyo, Japan) were evaluated for their ability to identify methicillin-resistant Staphylococcus aureus (MRSA) and to distinguish strains of MRSA from borderline oxacillin-resistant S. aureus (BORSA; mecA-negative, oxacilli...
متن کاملAssessment of methicillin resistant Staphylococcus Aureus detection methods: analytical comparative study
Introduction The heterogeneous expression of methicillin resistance in Staphylococcus aureus (MRSA) affects the efficiency of tests available to detect it. The objective of this study was to assess four phenotypic tests used to detect MRSA. Methods This is an analytical comparative study conducted among sudanese patients during period from May 2012 to July 2014, Staphylococcus aureus strains ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of clinical microbiology
دوره 24 3 شماره
صفحات -
تاریخ انتشار 1986