Wear of polyethylene in artificial hip joints: superolateral wear of the acetabulum.

نویسنده

  • J Fisher
چکیده

The bearing couple of a polyethylene acetabular cup and a polished metal or ceramic femoral head has been a successful combination in hip arthroplasty for over 30 years, but it is now recognised that fine micron and submicron polyethylene wear particles can cause adverse cellular reactions which may lead to osteolysis and loosening. In prostheses showing high wear, the penetration of the femoral head into the acetabular cup often exceeds 2 mm after 10 to 15 years. Although the head does not wear through the cup, which may be over 8 mm thick, there is a significant amount of debris, typically over 600 mm. Most of these particles are less than a micron, and therefore in the size range for phagocytosis, resulting in inflammatory reactions and osteolysis. Recent studies of failed Charnley prostheses at 10 to 20 years have estimated that well over one thousand billion wear particles (10) are released into the tissue during this period. There is much interest in the wear of polyethylene since it can lead to the failure of hip arthroplasties. Wear, unlike elastic modulus or hardness, is not a specific property of a material but is a result of the system and conditions in which the materials articulate. The simplest laws of wear state that the volume produced is proportional to the load and the sliding distance, but many other factors dramatically affect the wear rate. These include: 1) Local damage or roughening of the polished femoral head. 2) Oxidative degradation after sterilisation by gamma irradiation in the presence of oxygen (p. 340 and Besong et al). 3) Multidirectional movement. Polyethylene molecules are orientated by the forces of friction in the primary direction concern. Until there is good evidence that the intra-articular procedure alone is as effective as a combined reconstruction there must be doubt about its continued use. In this respect, the longer-term results of the cohort described by Webb et al are of particular interest.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Genotoxic Potential of Novel Materials Used in Modern Hip Replacements for Young Patients

Total hip replacement (THR), one of the most successful and cost effective surgical interventions introduced in the last 50 or so years in medicine and the second most common elective operation in the UK (Sheldon et al., 1996, Garellick et al., 1998), owes most of its success to the introduction of hard-on-soft arthroplasty by Charnley. Arthroplasty (from the Greek ‘arthrosis’ = ‘joint’ and ‘-p...

متن کامل

Biotribology of a vitamin E-stabilized polyethylene for hip arthroplasty - Influence of artificial ageing and third-body particles on wear.

The objective of our study was to evaluate the influence of prolonged artificial ageing on oxidation resistance and the subsequent wear behaviour of vitamin E-stabilized, in comparison to standard and highly cross-linked remelted polyethylene (XLPE), and the degradation effect of third-body particles on highly cross-linked remelted polyethylene inlays in total hip arthroplasty. Hip wear simulat...

متن کامل

A patterned microtexture to reduce friction and increase longevity of prosthetic hip joints.

More than 285,000 total hip replacement surgeries are performed in the US each year. Most prosthetic hip joints consist of a cobalt-chromium (CoCr) femoral head that articulates with a polyethylene acetabular component, lubricated with synovial fluid. The statistical survivorship of these metal-on-polyethylene prosthetic hip joints declines significantly after 10 to 15 years of use, primarily a...

متن کامل

Effect of motion inputs on the wear prediction of artificial hip joints

Hip joint simulators have been largely used to assess the wear performance of joint implants. Due to the complexity of joint movement, the motion mechanism adopted in simulators varies. The motion condition is particularly important for ultra-high molecular weight polyethylene (UHMWPE) since polyethylene wear can be substantially increased by the bearing cross-shear motion. Computational wear m...

متن کامل

A 12-station anatomic hip joint simulator.

A novel 12-station hip joint simulator with an anatomic position of the prosthesis was designed and built. The motion of the simulator consists of flexion-extension and abduction-adduction. The load is of the double-peak type. The validation test was done with three similar 28 mm CoCr-polyethylene joints in diluted calf serum lubricant for 3.3 x 10(6) cycles. The bearing surfaces of the polyeth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 80 2  شماره 

صفحات  -

تاریخ انتشار 1998