Contrast-enhanced C-arm CT evaluation of radiofrequency ablation lesions in the left ventricle.

نویسندگان

  • Erin E Girard
  • Amin Al-Ahmad
  • Jarrett Rosenberg
  • Richard Luong
  • Teri Moore
  • Günter Lauritsch
  • Jan Boese
  • Rebecca Fahrig
چکیده

OBJECTIVES The purpose of this study was to evaluate use of cardiac C-arm computed tomography (CT) in the assessment of the dimensions and temporal characteristics of radiofrequency ablation (RFA) lesions. This imaging modality uses a standard C-arm fluoroscopy system rotating around the patient, providing CT-like images during the RFA procedure. BACKGROUND Both cardiac magnetic resonance (CMR) and CT can be used to assess myocardial necrotic tissue. Several studies have reported visualizing cardiac RFA lesions with CMR; however, obtaining CMR images during interventional procedures is not common practice. Direct visualization of RFA lesions using C-arm CT during the procedure may improve outcomes and circumvent complications associated with cardiac ablation procedures. METHODS RFA lesions were created on the endocardial surface of the left ventricle of 9 swine using a 7-F RFA catheter. An electrocardiographically gated C-arm CT imaging protocol was used to acquire projection images during iodine contrast injection and after the injection every 5 min for up to 30 min, with no additional contrast. Reconstructed images were analyzed offline. The mean and SD of the signal intensity of the lesion and normal myocardium were measured in all images in each time series. Lesion dimensions and area were measured and compared in pathologic specimens and C-arm CT images. RESULTS All ablation lesions (n = 29) were visualized and lesion dimensions, as measured on C-arm CT, correlated well with postmortem tissue measurements (linear dimensions: concordance correlation = 0.87; area: concordance correlation = 0.90. Lesions were visualized as a perfusion defect on first-pass C-arm CT images with a signal intensity of 95 HU lower than that of normal myocardium (95% confidence interval: -111 HU to -79 HU). Images acquired at 1 and 5 min exhibited an enhancing ring surrounding the perfusion defect in 24 lesions (83%). CONCLUSIONS RFA lesion size, including transmurality, can be assessed using electrocardiographically gated cardiac C-arm CT in the interventional suite. Visualization of RFA lesions using cardiac C-arm CT may facilitate the assessment of adequate lesion delivery and provide valuable feedback during cardiac ablation procedures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intraprocedure visualization of the esophagus using interventional C-arm CT as guidance for left atrial radiofrequency ablation.

RATIONALE AND OBJECTIVES During radiofrequency catheter ablation for atrial fibrillation, the esophagus is at risk for thermal injury. In this study, C-arm computed tomography (CT) was compared to clinical CT, without the administration of oral contrast, to visualize the esophagus and its relationship to the left atrium and the ostia of the pulmonary veins (PVs) during the radiofrequency ablati...

متن کامل

Clinical application of transcatheter arterial chemoembolization combined with synchronous C-arm cone-beam CT guided radiofrequency ablation in treatment of large hepatocellular carcinoma.

OBJECTIVE This work aimed to evaluate the safety and clinical efficacy of transcatheter arterial chemoembolization (TACE) combined with c-arm cone-beam CT guided synchronous radiofrequency ablation (RFA) in treatment of large hepatocellular carcinoma (HCC). METHODS 21 patients with large HCC were studied from January 2010 to March 2012. TACE combined with synchronous C-arm cone-beam CT guided...

متن کامل

Value of C-arm computed tomography in radiofrequency ablation of small lung lesions.

This study aimed to explore the value of C-arm computed tomography (CT) applications in radiofrequency ablation (RFA) of small lung lesions. The puncture success rate, cumulative survival rate, tumor response rate, complications, and radiation dose during C-arm CT-guided RFA of 36 small lung lesions in 34 patients were analyzed. In 35 RFA procedures for 36 small lung lesions, the puncture succe...

متن کامل

CT versus sonography for monitoring radiofrequency ablation in a porcine liver.

OBJECTIVE The objective of this study was to compare CT and sonography for monitoring radiofrequency (RF) lesions in porcine livers. SUBJECTS AND METHODS RF lesions (n = 12) were created in three pig livers by applying 13 min of current to a multielectrode RF probe with a target temperature of 95 degrees C. Helical unenhanced CT and corresponding axial sonography were performed before ablatio...

متن کامل

Contrast-enhanced US-guided radiofrequency ablation of hepatocellular carcinoma.

PURPOSE Contrast-enhanced ultrasound (US) has been shown to be an efficient imaging modality in guiding radiofrequency (RF) ablation of hepatocellular carcinomas (HCC). The purpose of the present study was to assess the usefulness of contrast-enhanced US in guiding RF ablation in patients with early-stage HCC that was not clearly visible on grayscale US or noncontrast computed tomography (CT). ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • JACC. Cardiovascular imaging

دوره 4 3  شماره 

صفحات  -

تاریخ انتشار 2011