Implementation of a Data Acquisition System for 2×2 Fiber Optic Taper Array Coupled Digital X-ray Detector

نویسندگان

  • Zhigang Zhao
  • Ru Wang
  • Jianheng Huang
  • Jinchuan Guo
  • Hanben Niu
چکیده

Fiber optic taper (FOP) array coupled digital x-ray detector can be an ideal choice for large area high resolution x-ray imaging, but its data acquisition system is a challenge, for the reasons such as restrictions of hardware design due to the shape of the FOP array, long distance control requirement in x-ray environment, and arrangement of data transmission sequence among multiple CCD/CMOS image sensors. A FPGA and ARM based data acquisition system for 2×2 FOP array coupled x-ray detector was implemented in this paper. We have finished all the procedures involving the data acquisition system, including hardware and PCB design, FPGA design, ARM and PC software development, and so on. The data acquisition process operates in parallel during parameters setting, 4 CMOS image sensors (LUPA-4000) timing driving, and DDR2 SDRAM data buffering, while it works in series when sending data from each FPGA to ARM and from ARM to PC. Experimental results showed that the data acquisition system worked steadily, and whole images of a custom-built calibration plate were achieved by butting images of the four individual CMOS image sensors’ in visible light test environment. This work could be a valuable foundation for realization of all kinds of FOP array coupled digital x-ray detec-

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SLD Detector Electronic System Summary : Detector Elements and Channel Count . Data Volume

The SLD detector consists of five major subsystems, each with associated front-end electronics and an integrated FASTBUS control and data acquisition system. This paper highlights the choices among electronic technologies that have been developed for the SLD detector electronics. The common control, calibration, and data acquisition architectures are described. The functions of selected SLD int...

متن کامل

Development of a new EM-CCD based X-ray detector for synchrotron applications

We have developed and successfully demonstrated a high speed, low noise camera system for crystallography and X-ray imaging applications. By coupling an EM-CCD to a 3:1 fibre optic taper and a CsI(Tl) scintillator it was possible to detect hard X-rays. This novel approach to hard X-ray imaging takes advantage of the low equivalent readout noise performance at high pixel readout frequencies of E...

متن کامل

A high-spatial-resolution fiber-optic-coupled CMOS imager with novel scintillator for high-energy x-ray applications

A fast, high-spatial-resolution detector for high-energy microscopy work is presented. The detector uses a 2160 x 2560 CMOS chip for fast framing (up to 100 Hz in full-frame mode), coupled by a fiber optic taper to a scintillating Terbium-doped fiber optic plate for excellent stopping power even at high energies. The field of view is 7mm × 8.6mm with a resolution of 9 microns. The sensitivity i...

متن کامل

The point-spread function of fiber-coupled area detectors

The point-spread function (PSF) of a fiber-optic taper-coupled CCD area detector was measured over five decades of intensity using a 20 µm X-ray beam and ~2000-fold averaging. The `tails' of the PSF clearly revealed that it is neither Gaussian nor Lorentzian, but instead resembles the solid angle subtended by a pixel at a point source of light held a small distance (~27 µm) above the pixel plan...

متن کامل

A fiber optic sensor for measuring glucose in aqueous solutions

In this paper, the set-up of a multi-mode fiber optic sensor for measuring glucose in aqueous solutions is investigated and evaluated. The basis of this sensor is based on the Fresnel Reflection. In this setup, a helium-neon laser is used as a light source, a fiber optic probe, photocell as detector and a digital multimeter. The statistical analysis of the recorded data shows a highly linear be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015