Simple technique for internal control of real-time amplification assays.

نویسندگان

  • Siegfried Burggraf
  • Bernhard Olgemöller
چکیده

BACKGROUND In real-time PCR assays, the most accurate way to identify false-negative results, e.g., those caused by PCR inhibitors, is to add to samples an internal control that will be coamplified with the target (e.g., pathogen) DNA. Current internal control procedures, however, which usually involve the introduction of a DNA fragment, are complex, time-consuming, and expensive. METHODS Single-stranded oligonucleotides, which contain little more than primer and probe binding sites, were used as internal controls in real-time PCR assays. Mismatches were included in the probe-binding region of the internal control oligonucleotide (ICO) to prevent probe-control hybridization during the fluorescence acquisition step of the PCR. Amplified ICOs were detected by melting point analysis. ICOs could be added directly to the sample material before DNA extraction. RESULTS To demonstrate the feasibility of the new approach, we designed ICOs for the LightCycler hybridization probe assays for Mycobacterium tuberculosis complex, hepatitis B virus, herpes simplex virus, and varicella zoster virus. In each case, the controls did not interfere with detection of the pathogen, but were clearly detectable during a subsequent melting point analysis. CONCLUSIONS A single-stranded oligonucleotide that mimics the target region of the pathogen but is clearly distinguishable from the target during melting point analysis can serve as a simple, cost-effective internal control for real-time amplification assays. Such control oligonucleotides are easy to design and inexpensive. A costly second probe system is not necessary. Moreover, the internally controlled assay uses only one fluorescence detection channel of the instrument, leaving the second channel free for multiplex applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of bacteriophage MS2 as an internal control in viral reverse transcription-PCR assays.

Diagnostic systems based on reverse transcription (RT)-PCR are widely used for the detection of viral genomes in different human specimens. The application of internal controls (IC) to monitor each step of nucleic acid amplification is necessary to prevent false-negative results due to inhibition or human error. In this study, we designed various real-time RT-PCRs utilizing the coliphage MS2 re...

متن کامل

Construction strategy for an internal amplification control for real-time diagnostic assays using nucleic Acid sequence-based amplification: development and clinical application.

An important analytical control in molecular amplification-based methods is an internal amplification control (IAC), which should be included in each reaction mixture. An IAC is a nontarget nucleic acid sequence which is coamplified simultaneously with the target sequence. With negative results for the target nucleic acid, the absence of an IAC signal indicates that amplification has failed. A ...

متن کامل

Straightforward procedure for internal control of real-time reverse transcription amplification assays.

Internal controls are crucial for reliable detection of pathogens in nucleic acid amplification assays. Without an internal control, a negative amplification result may mean that the sample contains no target or that the reaction failed. We recently described (1) the use of internal controls that consist of internal control oligonucleotides (ICOs) that contain little more than primer sites and ...

متن کامل

Rapid Detection of COVID-19 by RT-LAMP PCR Technique and its Comparison with Real-Time RT-PCR Method

Rapid antigen and antibody, serological tests, and RT ‑ PCR-based molecular methods are widely used for the detection of microorganisms worldwide. Objectives: This study aimed by Isothermal nucleic acid amplification techniques to detect the covid-19. Methods: In this study, 200 samples of nasopharynx and oropharynx were collected from Jamaran Heart Hospital in Tehran. Covid -19 was exami...

متن کامل

Improved internal control for molecular diagnosis assays

The two principal determining steps in molecular diagnosis are the amplification and the identification steps. Accuracy of DNA amplification is primarily determined by the annealing sequence of the PCR primer to the analyte DNA. Accuracy for identification is determined either by the annealing region of a labelled probe for the real time PCR analysis, or the annealing of a sequencing primer for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 50 5  شماره 

صفحات  -

تاریخ انتشار 2004