High-resolution 1 H-MRSI of the brain using short-TE SPICE.
نویسندگان
چکیده
PURPOSE To improve signal-to-noise ratio (SNR) for high-resolution spectroscopic imaging using a subspace-based technique known as SPectroscopic Imaging by exploiting spatiospectral CorrElation (SPICE). METHODS The proposed method is based on a union-of-subspaces model of MRSI signals, which exploits the partial separability properties of water, lipid, baseline and metabolite signals. Enabled by this model, a special scheme is used for accelerated data acquisition, which includes a double-echo CSI component used to collect a "training" dataset (for determination of the basis functions) and a short-TE EPSI component used to collect a sparse "imaging" dataset (for determination of the overall spatiospectral distributions). A set of signal processing algorithms are developed to remove the water and lipid signals and jointly reconstruct the metabolite and baseline signals. RESULTS In vivo 1 H-MRSI results show that the proposed method can effectively remove the remaining water and lipid signals from sparse MRSI data acquired at 20 ms TE. Spatiospectral distributions of metabolite signals at 2 mm in-plane resolution with good SNR were obtained in a 15.5 min scan. CONCLUSIONS The proposed method can effectively remove nuisance signals and reconstruct high-resolution spatiospectral functions from sparse data to make short-TE SPICE possible. The method should prove useful for high-resolution 1 H-MRSI of the brain. Magn Reson Med 77:467-479, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
منابع مشابه
High-resolution 1H-FID-MRSI of the human brain at 7T
High quality metabolic mapping of several important brain metabolites (NAA, Cho, Cr, Ins, Glu) was achieved for a 64×64 matrix with a 3.4×3.4×12 mm voxel size in six healthy subjects (Fig.1, Fig.2). Subcutaneous lipids were suppressed by an additional factor of ~12 compared to standard 32×32 matrix (Fig.3). Most notably, the ultra-short TE increased the signal-to-noise ratio of J-coupled resona...
متن کاملFast and high resolution MRSI without aliasing using online SFAS and multiple regions of support
Introduction When localized magnetic resonance spectroscopic imaging (MRSI) is performed, unperfected signal saturation outside the region of interest (ROI) is typically encountered. This undesired signal can cause aliasing and signal contamination if fast high resolution MRSI is conducted by simply reducing FOV (i.e. Zoom MRSI). Alternatively, one can use the sequential forward array selection...
متن کاملShort echo time in vivo prostate ¹H-MRSI.
Visualization of short echo time (TE) metabolites in prostate magnetic resonance spectroscopic imaging is difficult due to lipid contamination and pulse timing constraints. In this work, we present a modified pulse sequence to permit short echo time (TE=40ms) acquisitions with reduced lipid contamination for the detection of short TE metabolites. The modified pulse sequence employs the conforma...
متن کاملAlgorithm for Lipid Suppression by Real-Time Isotropic Filter Design in Spectroscopic Brain Imaging
Introduction: Estimates of brain metabolites using whole-slice or large-volume magnetic resonance spectroscopic imaging (MRSI) are severely hampered by strong lipid signals even though the interfering signal arises from regions outside of the brain, namely subcutaneous tissue, scalp, and bone marrow. Many lipid suppression methods have been proposed, including outer-volume suppression (OVS) [1-...
متن کاملUltra-high resolution brain metabolite mapping at 7 T by short-TR Hadamard-encoded FID-MRSI
MRSI in the brain at ≥7 T is a technique of great promise, but has been limited mainly by low B0/B1+-homogeneity, specific absorption rate restrictions, long measurement times, and low spatial resolution. To overcome these limitations, we propose an ultra-high resolution (UHR) MRSI sequence that provides a 128×128 matrix with a nominal voxel volume of 1.7×1.7×8mm3 in a comparatively short measu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Magnetic resonance in medicine
دوره 77 2 شماره
صفحات -
تاریخ انتشار 2017