Assessment of flow velocity reserve by transthoracic Doppler echocardiography and venous adenosine infusion before and after left anterior descending coronary artery stenting.

نویسندگان

  • F Pizzuto
  • P Voci
  • E Mariano
  • P E Puddu
  • G Sardella
  • A Nigri
چکیده

OBJECTIVES We sought to evaluate whether coronary flow velocity reserve (CFR) (the ratio between hyperemic and baseline peak flow velocity), as measured by transthoracic Doppler echocardiography during adenosine infusion, allows detection of flow changes in the left anterior descending coronary artery (LAD) before and after stenting. BACKGROUND The immediate post-stenting evaluation of CFR by intracoronary Doppler has shown mixed results, due to reactive hyperemia and microvascular stunning. Noninvasive coronary Doppler echocardiography may be a more reliable measure than intracoronary Doppler. METHODS Transthoracic Doppler echocardiography during 90-s venous adenosine infusion (140 microg/kg body weight per min) was used to measure CFR of the LAD in 45 patients before and 3.7 +/- 2 days after successful stenting, as well as in 25 subjects with an angiographically normal LAD (control group). RESULTS Adequate Doppler spectra were obtained in 96% of the patients. Pre-stent CFR was significantly lower in patients than in control subjects (diastolic CFR: 1.45 +/- 0.5 vs. 2.72 +/- 0.71, p < 0.01; systolic CFR: 1.61 +/- 1.02 vs. 2.41 +/- 0.68, p < 0.01) and increased toward the normal range after stenting (diastolic CFR: 2.58 +/- 0.7 vs. 2.72 +/- 0.75, p = NS; systolic CFR: 2.43 +/- 1.01 vs. 2.41 +/- 0.52, p = NS). Diastolic CFR was often damped, suggesting coronary steal in patients with > or =90% versus <90% LAD stenosis (0.86 +/- 0.23 vs. 1.69 +/- 0.43, p < 0.01). Coronary stenting normalized diastolic CFR in these two groups (2.45 +/- 0.77 and 2.64 +/- 0.69, respectively, p = NS), even though impaired diastolic CFR persisted in three of four patients with > or =90% stenosis. Stenosis of the LAD was better discriminated by diastolic (F = 49.30) than systolic (F = 12.20) CFR (both p < 0.01). CONCLUSIONS Coronary flow reserve, as measured by transthoracic Doppler echocardiography, is impaired in LAD disease; it may identify patients with > or =90% stenosis; and it normalizes early after stenting, even in patients with > or =90% stenosis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

CARDIOVASCULAR MEDICINE Can coronary flow velocity reserve determined by transthoracic Doppler echocardiography predict the recovery of regional left ventricular function in patients with acute myocardial infarction?

Objective: To determine whether the early assessment of coronary flow velocity reserve (CFVR) by transthoracic Doppler echocardiography (TTDE) can predict myocardial viability after revascularisation in patients with acute myocardial infarction. Methods: 29 patients with anterior acute myocardial infarction who were successfully treated by coronary angioplasty were studied. TTDE was used to rec...

متن کامل

Non-invasive measurement of coronary flow reserve in children with Kawasaki disease.

OBJECTIVE To investigate whether transthoracic Doppler echocardiography (TTE) can reliably measure the coronary flow reserve in the left anterior descending coronary artery in children with Kawasaki disease. DESIGN Coronary flow velocity in the distal left anterior descending coronary artery was measured by TTE and was compared with that obtained by intracoronary Doppler guide wire. The ratio...

متن کامل

New noninvasive method for coronary flow reserve assessment: contrast-enhanced transthoracic second harmonic echo Doppler.

BACKGROUND We tested the hypothesis that blood flow velocity could be recorded in the left anterior descending coronary artery (LAD) during transthoracic echocardiography by use of second harmonic echo Doppler modality along with contrast enhancement (intravenous Levovist) at rest and after pharmacologically induced maximal vasodilation to assess coronary flow reserve (CFR) with a totally nonin...

متن کامل

Physiologic Assessment of Coronary Artery Stenosis by Coronary Flow Reserve Measurements With Transthoracic Doppler Echocardiography: Comparison With Exercise Thallium-201 Single-Photon Emission Computed Tomography

OBJECTIVES We evaluated the value of coronary flow reserve (CFR), as determined by transthoracic Doppler echocardiography (TTDE), for physiologic assessment of coronary artery stenosis severity, and we compared TTDE measurements with those obtained by exercise thallium201 (Tl-201) single-photon emission computed tomography (SPECT). BACKGROUND Coronary flow reserve measurements by TTDE have been...

متن کامل

Assessment of coronary flow reserve with transthoracic Doppler echocardiography: comparison with intracoronary Doppler method.

To evaluate the feasibility and usefulness of transthoracic Doppler echocardiography (TTDE) as a non-invasive method in recording distal anterior descending (LAD) coronary flow velocity, we compared coronary flow reserve (CFR) measured by TTDE with measurements by intracoronary Doppler wire (ICDW). Twenty-one patients without LAD stenosis were studied. ICDW performed at baseline and after intra...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 38 1  شماره 

صفحات  -

تاریخ انتشار 2001