Pediatric reference values for respiratory resistance measured by forced oscillation.
نویسندگان
چکیده
OBJECTIVES To determine, in North American children, reference values for respiratory resistance measurements by the forced oscillation (Rfo) technique and to examine whether sitting height, as index of truncal length, is a better determinant of resistance, less influenced by race and gender, than standing height. DESIGN/SETTING A prospective cross-sectional study of healthy nonobese children, carefully selected for absence of atopy, exposure to tobacco smoke, and recent upper respiratory tract infection. MEASUREMENTS Three measurements of respiratory resistance by forced oscillation were obtained at the fixed frequencies of 8 Hz (Rfo8), 12 Hz (Rfo12), and at 16 Hz (Rfo16) using the Custo Vit R (Custo Med GMBH; Munich, Germany). In cooperative children, routine spirometry (FEV1, FVC, and peak expiratory flow rate [PEFR]) was also performed. RESULTS We recruited 217 healthy children aged 3 to 17 years. Reproducible measurements of Rfo8 were obtained for 206 children, Rfo12 for 197 children, and Rfo16 for 209 children. Normal FEV1, FVC, and PEFR values were documented in all 69 subjects who were able to reproducibly cooperate with spirometry. Multiple linear regression identified measurements of either sitting or standing height as the best, and equally strong, determinants of respiratory resistance at all three frequencies. Gender and race were not important factors once either sitting or standing height measurement was considered. Our regression equations at 8 Hz are comparable to published reference values obtained at fixed frequencies of 6, 8, and 10 Hz using other instruments. However, in comparison to our results, prior values tended to underestimate resistance in the shortest children or to overestimate it in the tallest ones. Our regression equation for Rfo12 is similar to the only previously published one, while no reference values at 16 Hz were available for comparison. CONCLUSIONS Height is the best predictor for total respiratory resistance at 8, 12, and 16 Hz in children aged > or = 3 years. Use of sitting height does not appear to be a stronger determinant of resistance than standing height.
منابع مشابه
Normal values for respiratory resistance using forced oscillation in subjects>65 years old.
The aim of the present study was to determine reference values and predictive variables for respiratory impedance (Zrs) by the forced oscillation technique (FOT) in subjects aged>65 yrs. The investigation involved a prospective study of nonsmoking subjects, with normal forced expiratory volumes. The Zrs parameters, which included average resistance between 4-16 Hz (R4-16), average resistance be...
متن کاملAssessment of bronchial reactivity by forced oscillation admittance avoids the upper airway artefact.
The forced oscillation technique (FOT) allows easy assessment of bronchial reactivity. The use of a standard FOT generator (SG) results in changes in respiratory system resistance (delta Rrs,SG) which are affected by an artefact caused by the extrathoracic upper airway (EUA). The aim was to improve the FOT assessment of bronchial reactivity with the SG by computing the change in FOT admittance ...
متن کاملReference values for respiratory system impedance by using impulse oscillometry in children aged 2-11 years.
The forced oscillation technique makes it possible to evaluate the mechanical properties of the respiratory system with a minimum of cooperation. The method is therefore especially useful in children. Impulse oscillometry (IOS) is a commercially available version of this technique. There is, as yet, limited information on reference values for IOS in children. The aim of this study was to extend...
متن کاملReference ranges for Mexican preschool-aged children using the forced oscillation technique.
INTRODUCTION Recently, multi-ethnic reference ranges for spirometry have been created for use worldwide. In comparison, forced oscillation technique (FOT) reference values are limited to specific equipment and study populations, with current FOT reference ranges created in a Caucasian population. We aimed to develop FOT reference ranges for preschool-aged Mexican children and to compare these w...
متن کاملRespiratory function in healthy young children using forced oscillations.
BACKGROUND Monitoring of respiratory function is important in the diagnosis and management of respiratory disease. The forced oscillation technique requires minimal patient cooperation and is ideal for the determination of respiratory function in young children. This study aimed to develop reference ranges and to document the repeatability in healthy young children using commercially available ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Chest
دوره 113 5 شماره
صفحات -
تاریخ انتشار 1998