Sequential injection titration with spectrophotometric detection for the assay of acidity in fruit juices.
نویسندگان
چکیده
A simple sequential injection analysis (SIA) with spectrophotometric detection for an assay of acidity in fruit juice was investigated. An alkaline reagent (sodium hydroxide), a sample and an indicator (phenolphthalein) were first aspirated and stacked as adjacent zones in a holding coil. With flow reversal through a reaction coil to the detector, zone penetration occurred, leading to a neutralization reaction that caused a decrease in the color intensity of the indicator being monitored for absorbance at 552 nm. The effects of various parameters were studied. Linear calibration graphs for acidities of 0.2 - 1.0 and 0.5 - 2.5% w/v citric acid as a standard, with a relative standard deviation of 1% (acidity of 0.3 - 0.6% w/v as citric acid, n=11) and a sample throughput of 30 samples h(-1), were achieved. The developed method was validated by a standard titrimetric method for assaying the acidity of fruit juice samples.
منابع مشابه
Erosive Potential of Soft Drinks in Nigeria
The aim of this study was to assess the erosive potential of some soft drinks commonly consumed in Nigeria. A range of popular carbonated drinks (cola and non-cola) and fruit juices were selected. On two occasions, the followings were determined; (1) the pH, measured by a digital pH meter on opening of the packaging can or bottle. (2) The volume of 1.0M sodium hydroxide required to raise the pH...
متن کاملA Peroxidase-linked Spectrophotometric Assay for the Detection of Monoamine Oxidase Inhibitors
To develop a new more accurate spectrophotometric method for detecting monoamine oxidase inhibitors from plant extracts, a series of amine substrates were selected and their ability to be oxidized by monoamine oxidase was evaluated by the HPLC method and a new substrate was used to develop a peroxidase-linked spectrophotometric assay. 4-(Trifluoromethyl) benzylamine (11) was proved to be an exc...
متن کاملFlow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine
A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detec...
متن کاملA Peroxidase-linked Spectrophotometric Assay for the Detection of Monoamine Oxidase Inhibitors
To develop a new more accurate spectrophotometric method for detecting monoamine oxidase inhibitors from plant extracts, a series of amine substrates were selected and their ability to be oxidized by monoamine oxidase was evaluated by the HPLC method and a new substrate was used to develop a peroxidase-linked spectrophotometric assay. 4-(Trifluoromethyl) benzylamine (11) was proved to be an exc...
متن کاملSPECTROPHOTOMETRIC AND GAS CHROMATOGRAPHIC METHODS FOR DETECTION AND ASSAY OF MUSTARD GAS
A colorimetric method for detection and assay of mustard gas in urine after addition of thymolphthalein is reported. The detection limit was 80 ng/ml of llrine. Mustard gas could also be detected in urine after extraction with gas chromatography using FID detector. The detection limit was 10 ng/ml. In addition, thiodiglycol, a metabolite of mustard gas, could be converted to mustard with ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 22 1 شماره
صفحات -
تاریخ انتشار 2006