AIMS The positive predictive value of multidetector computed tomography angiography (CTA) for detecting significant stenosis remains limited. Possibly CTA may be more accurate in the evaluation of atherosclerosis rather than in the evaluation of stenosis severity. However, a comprehensive assessment of the diagnostic performance of CTA in comparison with both conventional coronary angiography (CCA) and intravascular ultrasound (IVUS) is lacking. Therefore, the aim of the study was to systematically investigate the diagnostic performance of CTA for two endpoints, namely detecting significant stenosis (using CCA as the reference standard) vs. detecting the presence of atherosclerosis (using IVUS as the reference of standard). METHODS AND RESULTS A total of 100 patients underwent CTA followed by both CCA and IVUS. Only those segments in which IVUS imaging was performed were included for CTA and quantitative coronary angiography (QCA) analysis. On CTA, each segment was evaluated for significant stenosis (defined as ≥ 50% luminal narrowing), on CCA significant stenosis was defined as a stenosis ≥ 50%. Second, on CTA, each segment was evaluated for atherosclerotic plaque; atherosclerosis on IVUS was defined as a plaque burden of ≥ 40% cross-sectional area. CTA correctly ruled out significant stenosis in 53 of 53 (100%) patients. However, nine patients (19%) were incorrectly diagnosed as having significant lesions on CTA resulting in sensitivity, specificity, positive, and negative predictive values of 100, 85, 81, and 100%. CTA correctly ruled out the presence of atherosclerosis in 7 patients (100%) and correctly identified the presence of atherosclerosis in 93 patients (100%). No patients were incorrectly classified, resulting in sensitivity, specificity, positive, and negative predictive values of 100%. Conclusions The present study is the first to confirm using both CCA and IVUS that the diagnostic performance of CTA is superior in the evaluation of the presence or the absence of atherosclerosis when compared with the evaluation of significant stenosis.
منابع مشابه
Non-invasive detection and assessment of coronary artery disease with multidetector-row computed tomography.
The fast volume coverage of retrospective ECG-gated multidetector-row helical CT(MDCT)arrows for acquisition of the entire heart volume with nearly isotropic spatial resolution(0.5×0.5×0.6 mm)within a single breath-hold. The sub-millimeter spatial resolution enables depiction of the major and also of peripheral coronary artery segments with lumen diameter down to 1 mm. The results of studies of...
متن کاملMulti-slice computed tomography: Can it adequately rule out left main coronary disease in patients with an intermediate probability of coronary artery disease?
BACKGROUND Multi-slice computed tomography (MSCT) is a fast-growing technology that permits a non-invasive, yet reliable, assessment of coronary atherosclerosis. We sought to explore the diagnostic accuracy of MSCT angiography in the detection of significant stenosis of the left main coronary artery (LMCA) in a series of patients with an intermediate pre-test likelihood of coronary artery disea...
متن کاملNon-invasive anatomical and functional imaging for the detection of coronary artery disease.
Coronary artery disease (CAD) is still an important cause of morbidity and mortality in the Western world. The gold standard for assessing significant coronary artery stenosis is invasive coronary angiography. Several disadvantages of the technique in combination with the fact that a substantial number of patients referred for conventional angiography appear free from significant stenosis have ...
متن کاملDiagnostic performance of 64-row coronary CT angiography in detecting significant stenosis as compared with conventional invasive coronary angiography
BACKGROUND The aim of the present study is to evaluate the accuracy of 64-multidetector-row computed tomography angiography (CTA) in comparison to conventional invasive angiography (CIA) in the diagnosis of significant stenosis (≥ 50%) of coronary artery tree. METHODS Assessment of CTA in the detection of coronary artery disease (CAD) was performed in patients referred because of symptoms or ...
متن کاملAccuracy of MSCT Coronary Angiography with 64 Row CT Scanner—Facing the Facts
Improvements in multislice computed tomography (MSCT) angiography of the coronary vessels have enabled the minimally invasive detection of coronary artery stenoses, while quantitative coronary angiography (QCA) is the accepted reference standard for evaluation thereof. Sixteen-slice MSCT showed promising diagnostic accuracy in detecting coronary artery stenoses haemodynamically and the subseque...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European heart journal
دوره 32 5 شماره
صفحات -
تاریخ انتشار 2011