Diagnostic value of direct examination of the protected specimen brush in ventilator-associated pneumonia.

نویسندگان

  • C H Marquette
  • F Wallet
  • R Nevière
  • M C Copin
  • F Saulnier
  • J N Drault
  • H Mehdaoui
  • D Mathieu
  • P Ramon
چکیده

Interpretation of the protected specimen brush (PSB) technique is based on quantitative bacterial cultures (QC), which unfortunately requires at least 24 h. We prospectively compared the diagnostic value of direct examination (DE) and QC of PSB specimens in 75 patients with suspected pneumonia. We also determined the optimal technique for DE. QC was performed using the serial dilution technique. From the original suspension, two cytospin slides were obtained and stained by the May-Grünwald Giemsa (MGG) and the Gram method for DE. If the prescreening on the MGG-stained slide was positive, the morphology and the Gram staining of the organisms were assessed on the Gram-stained slide. Using the 10(3) colony forming units (cfu.ml-1) threshold for defining PSB as positive or negative, DE had a sensitivity of 85% and a specificity of 94%. In a parallel in vitro study, 18 pairs of PSB specimens were collected from respiratory secretions inoculated with S. aureus. From each pair, one brush was processed as described above and the other was smeared on a glass slide prior to performance of QC. Using direct smear instead of cytocentrifuged preparation, slightly but significantly affected QC. Direct examination of cytospin slides is highly predictive of quantitative bacterial culture results, and provides rapid information regarding the Gram-stain morphology of the causative organisms. It may therefore guide initial therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pro/con clinical debate: The use of a protected specimen brush in the diagnosis of ventilator associated pneumonia

Although mechanical ventilation is instituted as a life-saving technique, it may lead to complications that can negatively impact on patients' morbidity and/or mortality. Ventilator associated pneumonia (VAP) is one such complication that is a common challenge to intensivists. Although most experts would agree that early 'appropriate' antibiotic use is essential in patients who develop VAP, the...

متن کامل

Diagnosis of ventilator-associated pneumonia: focus on nonbronchoscopic techniques (nonbronchoscopic bronchoalveolar lavage, including mini-BAL, blinded protected specimen brush, and blinded bronchial sampling) and endotracheal aspirates.

The ideal diagnostic approach for ventilator-associated pneumonia currently is based on invasive procedures to obtain respiratory tract cultures. Given the lack of consensus and relatively poor acceptance of full bronchoscopic bronchoalveolar lavage (BAL) and protected specimen brush (PSB), less invasive procedures have been developed. We review the nonbronchoscopic procedures (nonbronchoscopic...

متن کامل

"Blind" protected specimen brushing versus bronchoscopic techniques in the aetiolological diagnosis of ventilator-associated pneumonia.

The aetiological diagnosis of nosocomial pneumonia in intensive care unit (ICU) patients requires a valid, cheap and safe method. This method should be suitable for all mechanically-ventilated patients and all ICUs. The aim of this study was to assess the diagnostic yields of three methods: "blind" bronchial brushing (Accu-Cath)(protective specimen brush-nonbronchofibroscopic (PSB-non BF)); bro...

متن کامل

Protected specimen brush in the assessment of ventilator-associated pneumonia. Selection of a certain lung segment for bronchoscopic sampling is unnecessary.

The protected specimen brush (PSB) with quantitative cultures is one of the most reliable techniques for assessing pneumonia in mechanically ventilated (MV) patients. The need to select a certain lung segment for bronchoscopic sampling is still debated. We investigated whether the results of PSB specimens collected within an area radiographically involved with pneumonia (inv-PSB) differed from ...

متن کامل

Tracheal aspirate correlates with protected specimen brush in long-term ventilated patients who have clinical pneumonia.

STUDY OBJECTIVE This study was undertaken to determine whether tracheal aspirate cultures correlate with protected specimen brush (PSB) cultures in the diagnosis of probable ventilator-associated pneumonia (VAP). DESIGN Retrospective evaluation of 52 episodes of clinical pneumonia in 38 patients who underwent bronchoscopy and PSB as well as tracheal aspirate cultures. SETTING The study took...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 7 1  شماره 

صفحات  -

تاریخ انتشار 1994