Use of CT angiography and digital subtraction angiography in patients with ruptured cerebral aneurysm: evaluation of a large multihospital data base.

نویسندگان

  • J S McDonald
  • D F Kallmes
  • G Lanzino
  • H J Cloft
چکیده

BACKGROUND AND PURPOSE Both CT angiography and digital subtraction angiography are used to detect aneurysms in patients with subarachnoid hemorrhage. We examined a large multihospital data base to determine how practice is evolving with regard to the use of CT angiography and DSA in patients with ruptured cerebral aneurysm. MATERIALS AND METHODS The Premier Perspective data base was used to identify hospitalizations of patients treated with clipping or coiling of ruptured cerebral aneurysms from 2006-2011. Billing information was used to determine pretreatment and posttreatment use of DSA and CT angiography during hospitalization. RESULTS A total of 4972 patients (1022 clipping, 3950 coiling) at 116 hospitals were identified. The percentage of patients with SAH who underwent pretreatment CT angiography significantly increased from 20% in 2006 to 44% in 2011 (P < .0001), whereas the percentage of patients who underwent DSA remained unchanged from 96-94% (P = .28). This CT angiography trend was observed in coiling patients (17-42%, P < .0001) and clipping patients (32-54%, P < .0001). There was a significant increase in the percentage of patients who underwent posttreatment imaging from 41% in 2006 to 48% in 2011 (P = .0037). This trend was observed in clipping patients (33-65%, P < .0001) but not coiling patients (43-45%, P = .62). CONCLUSIONS For the pretreatment evaluation of ruptured aneurysms, the use of CT angiography increased from 2006-2011 without a corresponding decrease in the use of DSA. These results raise the question of potential redundancy without added clinical value of the second test.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Noninvasive detection of a ruptured aneurysm at a basilar artery fenestration with submillimeter multisection CT angiography.

The criterion standard for the detection of intracranial aneurysms is digital subtraction angiography. MR imaging and CT provide good accuracy in the evaluation of brain arteries and aneurysms. We herein report a case of a ruptured aneurysm at a basilar artery fenestration. The diagnosis was assessed with 16-row multisection CT angiography and was confirmed by using digital subtraction angiogra...

متن کامل

Diagnostic Accuracy of Computed Tomographic Angiography (CTA) in the Management of Aneurysmal Subarachnoid Haemorrhage (SAH)

Subarachnoid hemorrhage secondary to ruptured aneurysm is a critical clinical situation demanding a very skilled surgical and medical management. Until now cerebral digital subtraction angiography (DSA) has been used as the criterion standard for aneurysmal detection and planning of their microsurgical treatment. However, as the method for diagnosis of subarachnoid hemorrhage moved from lumbar ...

متن کامل

Volume subtraction three-dimensional CT angiography for cerebrovascular disease: report of two cases.

We report two cases in which volume subtraction three-dimensional CT angiography (VS-3DCTA) was used for cerebral aneurysm and vascular stenosis with intramural calcification. Case 1: VS-3DCTA with volume rendering clearly showed carotid cave aneurysm of the internal carotid artery. The location and size of the aneurysm was confirmed by digital subtraction angiography (DSA). In evaluation of th...

متن کامل

Angiographic appearance of a cerebral aneurysm rupture.

A 53-year-old woman was referred because a CT scan disclosed a subarachnoid hemorrhage. An aneurysm was seen on digital subtraction angiography, which suddenly ruptured (video 1 on the Neurology® Web site at Neurology.org) during the study, suggesting the cause of the hemorrhage (video 2). The rate of contrast emission was 3 mL/s with a total volume of 16 mL; the pressure was 200 psi. External ...

متن کامل

Computational replicas: anatomic reconstructions of cerebral vessels as volume numerical grids at three-dimensional angiography.

BACKGROUND AND PURPOSE We present a relatively simple approach that physicians can use to reconstruct cerebral vessels as 3D numerical grids or computational replicas. The method accurately duplicates their geometry to provide computer simulations of their blood flow. METHODS Initial images were obtained by using any medical imaging technique, such as MR angiography, CT angiography, or 3D dig...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 34 9  شماره 

صفحات  -

تاریخ انتشار 2013