Modal Performance Factor Testing Procedure for Base Isolation Systems
نویسنده
چکیده
SITUATION Almost indisputable belief that base isolation hardware should separate a building from shaking ground just by definition is extremely appealing. The examples are numerous. Sometimes, it was even stated that seismic forces in base isolated structures could be reduced by factor of 66 in comparison with conventional construction (Tajirian et al. 1990), though the degree of promised mitigation may vary. It is 10-20-fold per Rodwell et al. 1990, 7-fold per Bailey & Allen 1988 and Zayas et al. 1990, 5 to 10-fold per Volkinburg 1991, 5-fold per Amin & Mokha 1995, 6-fold per Bachman 1995, 5 to 10-fold per Buckle (Prendergast 1995). Although different in the specifics, all mentioned researchers and engineers predicted a sizable reduction of seismic forces in the buildings equipped with base isolators.
منابع مشابه
OPTIMAL HYBRID BASE ISOLATION AND MR DAMPER
In this paper, optimal design of hybrid low damping base isolation and magnetorheological (MR) damper has been studied. Optimal hybrid base isolation system has been designed to minimize the maximum base drift of low damping base isolation system where for solving the optimization problem, genetic algorithm (GA) has been used. In design procedure the maximum acceleration of the structure has ...
متن کاملOPTIMAL SMART BASE ISOLATION SYSTEM FOR MULTIPLE EARTHQUAKES
Hybrid control system composed of a base isolation system and a magneto-rheological damper so-called smart base isolation is one of effective semi-active control system in controlling the seismic response of structures. In this paper, a design method is proposed for designing the smart base isolation system in order to achieve an effective performance under multiple earthquakes. The base mass, ...
متن کاملImproving seismic performance of elevated cylindrical water storage tanks using nonlinear isolators incorporating liquid–structure interaction
Pervasive construction of elevated liquid tanks as the most important sources for urban hygienic water, and their failure under earthquake, highlighs the necessity for research toward new passive control devices. Design and use of base-isolation systems for elevated liquid tanks is propounded as a novel seismic engineering technology. To date, no special examination has been discussed in relati...
متن کاملA Simplified Modal Pushover Analysis-based Method for Incremental Dynamic Analysis of Regular RC Moment-resisting Frames
Incremental Dynamic Analysis (IDA) procedure is now considered as a robust tool for estimating the seismic sidesway collapse capacity of structures. However, the procedure is time-consuming and requires numerous nonlinear response-history analyses. This paper proposes a simplified Modal Pushover Analysis (MPA) procedure for IDA of RC moment-resisting frames. The proposed method uses the dynamic...
متن کاملMULTI-OBJECTIVE SEMI-ACTIVE BASE ISOLATION SYSTEM
Semi-active base isolation system has been proposed mainly to mitigate the base drift of isolated structures while in most cases, its application causes the maximum acceleration of superstructure to be increased. In this paper, designing optimal semi-active base isolation system composed of linear base isolation system with low damping and magneto-rheological (MR) damper has been studied for co...
متن کامل