A Turn-by-turn Vertical Profile Monitor

نویسندگان

  • R. Scott Smith
  • Stuart Henderson
  • D. Hartill
  • Tong Chen
چکیده

A turn-by-turn vertical beam profile monitor has been developed at the Cornell Electron Storage Ring (CESR). The instrument optically images the vertical beam distribution with an array of optical fibers that transport visible synchrotron radiation to an array of photo-multiplier tubes. Each PMT signal is recorded by a turn-by-turn data acquisition system. With this instrument, we compare profiles of colliding and non-colliding electron bunches, from which we calculate an upper limit on the coherent beam-beam effect.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automatic Phase Advancing in Switched Reluctance Motor by Employing an Electronic Governor for a Desired Speed Angle Profile

Switched reluctance motor (SRM) drive has remarkable characteristics that make it attractive for high-speed applications. As the motor's speed increases the shape of the current waveform changes in such way that limits the production of motoring torque. At high speeds, it is possible for the phase current never reaches the desired value due to the self e.m.f. of the motor, therefore, the torque...

متن کامل

Turn-by-Turn Imaging of the Transverse Beam Profile in PEP-II

During injection or instability, the transverse profile of an individual bunch in a storage ring can change significantly in a few turns. However, most synchrotron-light imaging techniques are not designed for this time scale. We have developed a novel diagnostic that enhances the utility of a fast gated camera by adding, inexpensively, some features of a dual-axis streak camera, in order to wa...

متن کامل

Recognition and Location of Power Transformer Turn to Turn Fault by Analysis of Winding Imposed Forces

Turn to turn fault is one of the major internal failures in the power transformers that if it is not quickly detected, can be extended and led to a complete transformer breakdown. So, the diagnosis and location of the turn to turn fault of the power transformer, as one of the most important equipment in the power system, is the main objective of this paper. For this purpose, a detailed model of...

متن کامل

Status of Low Emittance Tuning at CesrTA

We report on the status of emittance tuning techniques at the CESR Test Accelerator (CesrTA). The CesrTA experimental program requires that we operate in a variety of machine lattices, each with the smallest possible emittance. We utilize high-bandwidth BPM electronics for fast, precision measurements of orbit, betatron phase, transverse coupling, and dispersion. Analysis of the data and implem...

متن کامل

Stator Turn-to-Turn Fault Detection of Induction Motor by Non-Invasive Method Using Generalized Regression Neural Network

Condition monitoring and protection methods based on the analysis of the machine's current are widely used according to non-invasive characteristics of current transformers. It should be noted that, these sensors are installed by default in the machine control center. On the other hand, condition monitoring based on mathematical methods has been proposed in literature. However, they are model b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1997