Evaluation of a point-of-care electrochemical meter to detect subclinical ketosis and hypoglycaemia in lactating dairy cows.
نویسندگان
چکیده
OBJECTIVES To evaluate and validate a hand-held electrochemical meter (Precision Xtra®) as a screening test for subclinical ketosis and hypoglycaemia in lactating dairy cattle. DESIGN Method comparison study using a convenience sample. PROCEDURE Blood samples were collected into plain tubes from the coccygeal vessels of 181 Holstein cows at 2-4 weeks of lactation during summer in Iran. Blood β-hydroxybutyrate concentration (BHB) and glucose concentration were immediately measured by the electrochemical meter after applying 20 μL of blood to the reagent strip. Passing-Bablok regression and Bland-Altman plots were used to determine the accuracy of the meter against laboratory reference methods (BHB dehydrogenase and glucose oxidase). RESULTS Serum BHB ranged from 0.1 to 7.3 mmol/L and serum glucose ranged from 0.9 to 5.1 mmol/L. Passing-Bablok regression analysis indicated that the electrochemical meter and reference methods were linearly related for BHB and glucose, with a slope estimate that was not significantly different from 1.00. Clinically minor, but statistically significant, differences were present for the intercept value for Passing-Bablok regression analysis for BHB and glucose, and bias estimates in the Bland-Altman plots for BHB and glucose. CONCLUSION The electrochemical meter provided a clinically useful method to detect subclinical ketosis and hypoglycaemia in lactating dairy cows. Compared with other method validation studies using the meter, we attributed the improved performance of the electrochemical meter to application of a fixed volume of blood (20 μL) to the reagent strip, use of the meter in hot ambient conditions and use of glucose oxidase as the reference method for glucose analysis.
منابع مشابه
Evaluation of Total Antioxidant, Total Calcium, Selenium, Insulin, Free Triiodothyronine and Free Thyroxine Levels in Cows with Ketosis
Ketosis is an important metabolic disease of high milk-producing cows. There are significant changes in many metabolite and hormonal concentrations in metabolic diseases. This study was carried out to assess the concentrations calcium (Ca), selenium (Se), total antioxidant (TAOC), insulin, free triiodothyronine (fT3) and free thyroxine (fT4) in cows with subclinical and clinical ketosis. This s...
متن کاملConventional and extended intramammary therapy of persistent subclinical mastitis using nafcillin-penicillindihydrostreptomycin in lactating dairy cattle
The objective of the present study was to compare the efficacy of conventional and extendedintramammary (IMM) therapy of persistent subclinical mastitis in lactating dairy cattle using nafcillinpenicillin-dihydrostreptomycin combination (NPD). Sixty-five dairy cows with 126 infected quarters were enrolled in the study. Infected cows were allocated randomly to 1 of 3 different treatment regimens...
متن کاملRelationship between in vitroantimicrobial sensitivity of bovine subclinical mastitis isolates and treatment outcome in lactating dairy cows
The objective of the present study was to determine whether there was an association between the in vitroantimicrobial sensitivity test results of subclinical mastitis pathogensand bacteriological cure following intramammary treatment using a combination of nafcillin, penicillin, and streptomycin (NPS). Eighty-six intramammary pathogens from 43 cows were examined inthis study. Most intramammary...
متن کاملMilk Production, Milk Fatty Acid Profiles and Blood Metabolites in Holstein Dairy Cows Fed Diets Based on Dried Citrus Pulp
The objective of the present study was to determine the effect of substitution of corn grain with dried citrus pulp (DCP) on milk composition, fatty acids profiles and blood metabolites in Holstein dairy cows. These parameters were measured in a replicated 4 × 4 latin square design experiment using eight Holstein cows. Each experimental period lasted 4 weeks. The four treatments were: control (...
متن کاملEvaluation and use of three cowside tests for detection of subclinical ketosis in early postpartum cows.
The objective was to evaluate the performance of 3 cowside diagnostic tests for detection of subclinical ketosis, defined as a serum beta-hydroxybutyrate (BHBA) concentration >or=1400 micromol/L. On 16 d over a 5-mo period, samples of serum, milk, and urine were collected on a large dairy facility from cows of all parities between 2 and 15 DIM. The sample proportion of subclinical ketosis was 7...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Australian veterinary journal
دوره 95 4 شماره
صفحات -
تاریخ انتشار 2017