Analysis: New point-of-care blood glucose monitoring system for the hospital demonstrates satisfactory analytical accuracy using blood from critically ill patients--an important step toward improved blood glucose control in the hospital.
نویسنده
چکیده
Patients managed in the intensive care units (ICUs) and general wards of the hospital experience a high incidence of hyperglycemia, hypoglycemia, and glycemic variability, despite significant hospital resources devoted to glucose control. Optimized glucose meters and monitoring systems are required to improve the safety and efficacy of insulin delivery and glucose control in the hospital. Safe insulin dosing requires timely and accurate glucose measurements, especially during dynamic changes in nutrition, insulin sensitivity, and physiological stress. In the current issue of Journal of Diabetes Science and Technology, Mitsios and coauthors describe the analytical accuracy of the new Accu-Check® Inform II blood glucose (BG) monitoring system commercialized by F. Hoffmann-La Roche Ltd. The point-of-care glucose meter achieved the desired degree of accuracy and precision, as defined by Clinical and Laboratory Standards Institute POCT12-A3 guidelines when evaluated using venous blood from 600 critically ill patients from multiple ICUs at two medical centers. Venous whole blood samples were used to obtain glucose meter results in duplicate. The remaining blood sample was centrifuged to obtain plasma for central hospital laboratory testing using the hexokinase method within 5 min of meter testing. A total of 98.8% of the 1200 Accu-Check Inform II meter's glucose values were within ± 12.5% (± 12 mg/dl) of the mean laboratory glucose value, and 99.8% were within ± 20% (± 20 mg/dl), thus meeting the Clinical and Laboratory Standards Institute criteria. Future studies are required to evaluate the clinical performance of the new BG monitoring system in the intended-use patient populations and critical care environments, using arterial, peripheral venous, central venous, and capillary blood samples.
منابع مشابه
Analytical Performance and Quality Control of a Glucose Monitor System
Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...
متن کاملBedside Glucose Monitoring—Is it Safe? A New, Regulatory-Compliant Risk Assessment Evaluation Protocol in Critically Ill Patient Care Settings*
OBJECTIVES New data have emerged from ambulatory and acute care settings about adverse patient events, including death, attributable to erroneous blood glucose meter measurements and leading to questions over their use in critically ill patients. The U.S. Food and Drug Administration published new, more stringent guidelines for glucose meter manufacturers to evaluate the performance of blood gl...
متن کاملFractional Order Glucose Insulin System Using Fractional Back-Stepping Sliding Mode Control
In this paper, based on a fractional order Bergman minimal model, a robust strategy for regulationof blood glucose in type 1 diabetic patients is presented. Glucose/insulin concentration in the patientbody is controlled through the injection under the patients skin by the pump. Many various con-trollers for this system have been proposed in the literature. However, most of the...
متن کاملA System for Continuous Estimating and Monitoring Cardiac Output via Arterial Waveform Analysis
Background: Cardiac output (CO) is the total volume of blood pumped by the heart per minute and is a function of heart rate and stroke volume. CO is one of the most important parameters for monitoring cardiac function, estimating global oxygen delivery and understanding the causes of high blood pressure. Hence, measuring CO has always been a matter of interest to researchers and clinicians. Sev...
متن کاملThe Mealtime Challenge: Nutrition and Glycemic Control in the Hospital
Management of diabetes and hyperglycemia has become an important quality care indicator in the hospital setting. Multiple health care organizations offer guidelines for glycemic control, including recommendations for medical nutrition therapy (MNT) and consistent-carbohydrate meal plans.1–4 Additionally, the appropriate timing of nutrition delivery, point-ofcare (POC) blood glucose monitoring, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of diabetes science and technology
دوره 7 5 شماره
صفحات -
تاریخ انتشار 2013