Analysis of the Nova Stat Strip® glucose meter for real-time blood glucose determinations during glucose clamp studies: "don't swap horses in midstream".

نویسنده

  • Lutz Heinemann
چکیده

Proper performance of glucose clamps is critically dependent on reliable blood glucose (BG) measurements. A number of requirements have to be fulfilled by a system that aims to replace the laboratory devices that are currently in use. Many more aspects need to be taken into account besides the accuracy of BG measurement. It might very well be that the BG meter studied by Rabiee and colleagues in this issue of Journal of Diabetes Science and Technology fulfills most or all of such requirements; however, these aspects have to be tested more thoroughly before one switches from an established measurement method to the Nova Stat Strip® glucometer.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accuracy and reliability of the Nova StatStrip® glucose meter for real-time blood glucose determinations during glucose clamp studies.

AIMS/HYPOTHESIS The Andres clamp technique, which requires accurate and timely determination of glucose, utilizes the Beckman or Yellow Springs Instruments (YSI) glucose analyzers. Both instruments require maintenance, a dedicated operator, preparation of a plasma sample, and a duplicate measurement that takes ≥2 minutes. The Nova StatStrip glucose meter was evaluated for accuracy, reliability,...

متن کامل

Laboratory evaluation of the Glucocard blood glucose test meter.

The Glucocard (Kyoto Daiichi Kagaku) blood glucose meter is designed for self-monitoring of blood glucose concentrations in capillary blood through use of an electrochemical test strip. Evaluated in this laboratory, the Glucocard had CVs of 4.6%, 6.6%, and 3.5% at blood glucose concentrations of 2.4, 4.1, and 18.9 mmol/L, respectively. The meter's response varied linearly with blood glucose con...

متن کامل

Comparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs

Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...

متن کامل

Hematocrit interference of blood glucose meters for patient self-measurement.

BACKGROUND Abnormal hematocrit levels may interfere with glucose readings of patient self-assessment blood glucose (BG) meters. The aim of this laboratory investigation was to assess the potential influence of hematocrit variations on a variety of BG meters applying different measurement technologies. METHODS Venous heparinized blood was manipulated to contain three different BG concentration...

متن کامل

مقایسه قدرت دستگاه گلوکومتر Accu-chek با Elite در تشخیص دیابت با استفاده از خونریزی متعاقب Probing

Abstract Background: Recent studies have assessed the validity of glucometer devices in estimating the glucose level of gingival blood during routine periodontal examination (Bleeding On Probing). The purpose of this study was to evaluate whether blood oozing from gingival tissues during routine periodontal examination can be used for determining g...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of diabetes science and technology

دوره 4 5  شماره 

صفحات  -

تاریخ انتشار 2010