Impaired left ventricular function in chronic aortic valve disease: survival and function after replacement by Björk-Shiley prosthesis.

نویسندگان

  • F Schwarz
  • W Flameng
  • F Langebartels
  • M Sesto
  • P Walter
  • M Schlepper
چکیده

Postoperative survival and left ventricular function were studied in 128 patients who underwent isolated aortic valve replacement by the Björk-Shiley valve between 1973 and 1977. The average follow-up was 2.1 years. Patients with associated coronary artery disease or mitral valve disease were excluded. Preoperative ejection fraction ranged from 15-84%. Forty-two patients were restudied by cardiac catheterization 9.1 +/- 1.1 months (mean +/- SEM) after valve replacement. The hospital mortality was 11%. Preoperative type of valve lesion, functional class, cardiothoracic ratio, and ejection fraction (EF) had no significant effect on postoperative survival up to 4 years. After operation, left ventricular mass (LVMI) and peak systolic wall stress (PSWS) fell significantly, while EF and mean normalized systolic ejection rate (MNSER) increased in aortic stenosis and in aortic insufficiency. Neither in aortic stenosis nor in aortic insufficiency was there a significant relation between preoperative ejection fraction and postoperative LVMI, EF, MNSER and PSWS. We attributed this to a marked improvement of left ventricular function in patients with preoperative impaired ventricular function. Six patients with paravalvular leak to restudy has a significantly lower EF and MNSER, and a higher PSWS than patients without leak. Patients without leak had normal EF, MNSER and PSWS when compared with 10 normal persons, but LVMI remained moderately elevated. Postoperative transprosthetic gradient was 11.9 mm Hg (range 0-64 mm Hg). We conclude that impaired cardiac function is completely restored after aortic valve replacement by Björk-Shiley valve, if valve function is good. Patients with impaired cardiac function preoperatively did not have a poorer prognosis after operation than patients with normal function.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left ventricular function before and following double valve replacement by Björk-Shiley prostheses.

Postoperative survival and cardiac function were studied in 45 patients who underwent combined mitral and aortic valve replacement by Bjork-Shiley prostheses between 1971 and 1977. The average follow-up was three years. Pre-operative left ventricular ejection fraction ranged from 28 to 78% (mean 57%). The hospital mortality rate for the entire series was 18%, the five year survival rate 58%. Ho...

متن کامل

Right ventricular Hemodynamic Alteration after Pulmonary Valve Replacement in Children with Congenital Heart Disease

Introduction:  In patients who underwent surgery to repair Tetralogy of Fallot, right ventricular dilation from pulmonary regurgitation may be result in right ventricular failure, arrhythmias and cardiac arrest. Hence, pulmonary valve replacement may be necessary to reduce right ventricular volume overload. The aim of present study was to assess the effects of pulmonary valve replacement on rig...

متن کامل

Red cell survival after aortic valve replacement with Björk-Shiley prosthesis in presence of sickle-cell trait.

A case of aortic valve replacement with a Björk-Shiley disc prosthesis in a patient with sickle-cell trait is presented. Six months after operation red cell survival was not significantly reduced. On theoretical and clinical grounds it is concluded that the presence of sickle-cell trait does not contribute to late postoperative haemolysis after heart valve replacement.

متن کامل

The Effect of Aortic Valve Replacement

We retrospectively studied 252 operated and 47 unoperated patients with isolated aortic valve disease. Aortic valve replacement (AVR) was recommended to all patients based on clinical and hemodynamic data. Preoperative hemodynamic and angiographic data were similar in operated and unoperated cohorts. Seventy-one percent of patients received a Bjork-Shiley prosthesis. Operative mortality was 7% ...

متن کامل

Echocardiographic assessment of left ventricular filling characteristics after mitral valve replacement with the St Jude medical prosthesis.

The major cause of late mortality and morbidity after prosthetic valve replacement is thromboembolism. The nidus for initiation of thrombus formation has been blood metal interfaces, and a new valve--the St Jude prosthesis--has therefore been developed without any metal components. We have assessed echocardiographically in 27 patients the effects of this valve on left ventricular filling charac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 60 1  شماره 

صفحات  -

تاریخ انتشار 1979