Evaluation of the Amniostat-FLM assay for assessment of fetal lung maturity.

نویسندگان

  • G Lockitch
  • B K Wittmann
  • S M Mura
  • L C Hawkley
چکیده

Results of the "Amniostat-FLM" assay, a rapid semiquantitative test for phosphatidylglycerol, were compared with determinations of the lecithin/sphingomyelin (L/S) ratio, with phosphatidylglycerol measured by two-dimensional thin-layer chromatography, and with results of the "shake test" for 94 specimens of amniotic fluid. Correlation between results with the Amniostat and the other tests was excellent. All four tests are very accurate when predicting lung maturity. The predictive value of a negative test, i.e., that hyaline membrane disease would not occur, was between 92 and 100%. However, the accuracy of predicted lung immaturity is poor. For all four tests, predictions of lung immaturity were incorrect in more than 50% of the cases. Of the 49 infants born within 72 h of testing, none developed hyaline membrane disease when phosphatidylglycerol was detectable by either method or when the shake test indicated fetal lung maturity, but three infants with L/S ratio greater than 2/1 did develop the disease. The Amniostat provides a rapid screening method for detecting phosphatidylglycerol in amniotic fluid, which could well replace the thin-layer chromatographic method for measuring phosphatidylglycerol in the panel of diagnostic tests for fetal lung maturity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three methods compared for determining phosphatidylglycerol in amniotic fluid.

Phosphatidylglycerol is one component of amniotic fluid that is unaffected by several of the reported interferences with conventional thin-layer chromatographic measurement of phospholipid. To compare a rapid immunological agglutination test, "Amniostat-FLM", with two-dimensional thin-layer chromatography, we determined phosphatidylglycerol by both methods in 41 amniotic fluid specimens obtaine...

متن کامل

Analytical and clinical evaluation of refractive index-matched anomalous diffraction (RIMAD) for assessment of fetal lung maturation.

We have evaluated refractive index-matched anomalous defraction (RIMAD) (Dubin SB, Clin Chem 1988;34:938-43) as a potential method for assessment of fetal lung maturity (FLM). This method determines the total light scattered by the surfactant-containing lamellar bodies by subtraction of the A650 from amniotic fluid diluted in glycerol from that of amniotic fluid diluted in distilled water. It i...

متن کامل

Assessment of the diagnostic accuracy of the TDx-FLM II to predict fetal lung maturity.

BACKGROUND Because respiratory distress syndrome (RDS) affects 1% of live births, accurate and rapid assessment of markers of fetal lung maturity is critical to clinicians in deciding whether to deliver a preterm infant. Our objective was to determine the optimal diagnostic cutoff value for the TDx-FLM II assay (Abbott Laboratories) for predicting clinically significant RDS. METHODS Amniotic ...

متن کامل

Evaluation of the PG-Numeric assay for semi-automated analysis for phosphatidylglycerol in amniotic fluid.

We evaluated the performance of the PG-Numeric (PGN; Isolab, Inc.) enzymatic assay for phosphatidylglycerol (PG) adapted for semi-automated analysis on the Cobas-Bio (Roche) centrifugal analyzer. We evaluated precision, linearity, and potential interference from endogenous glycerol. In addition, we compared the results of the PGN assay with those for two other PG assays. Amniostat-FLM (AFLM; Ha...

متن کامل

Preanalytical factors that influence the Abbott TDx Fetal Lung Maturity II assay.

BACKGROUND The TDx Fetal Lung Maturity II (FLM II) assay uses amniotic fluid to assess lung maturity of the unborn infant. We investigated common preanalytical factors that influence FLM results, including centrifugation, sample storage, and contamination by whole blood. METHODS We tested 18 specimens after centrifugation and after resuspension by vortex-mixing. We also analyzed 23 specimens ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 30 7  شماره 

صفحات  -

تاریخ انتشار 1984