Tremor suppression through impedance control.
نویسندگان
چکیده
This paper presents a method for designing tremor suppression systems that achieve a specified reduction in pathological tremor power through controlling the impedance of the human-machine interface. Position, rate, and acceleration feedback are examined and two techniques for the selection of feedback coefficients are discussed. Both techniques seek a desired closed-loop human-machine frequency response and require the development of open-loop human-machine models through system identification. The design techniques were used to develop a tremor suppression system that was subsequently evaluated using human subjects. It is concluded that nonadaptive tremor suppression systems that utilize impedance control to achieve a specified reduction in tremor power can be successfully designed when accurate open-loop human-machine models are available.
منابع مشابه
Optimal design of a vibration absorber for tremor control of arm in Parkinson's disease
Because the underlying physiology of pathological tremor in a Parkinson's patient is not well understood, the existing physical and drug therapies have not been successful in tremor treatment. Different mathematical modeling of such vibration has been introduced to investigate the problem and reduce the existing vibration. Most of the models have represented the induced vibration as a sinusoida...
متن کاملSuppression of Hand Postural Tremor Via Active Force Control Method
This paper presents the behavior and the effective way to suppress the human hand postural tremor using the active force control method. The main advantages of proposed method include; its simple control technique, practically applicable in real-time due to the much lesser computational burden and the extra robustness feature the method generates. The actual tremor data from a Parkinson disease...
متن کاملPhase dependent modulation of tremor amplitude in essential tremor through thalamic stimulation
High frequency deep brain stimulation of the thalamus can help ameliorate severe essential tremor. Here we explore how the efficacy, efficiency and selectivity of thalamic deep brain stimulation might be improved in this condition. We started from the hypothesis that the effects of electrical stimulation on essential tremor may be phase dependent, and that, in particular, there are tremor phase...
متن کاملBilateral Telemanipulation with Guidance Virtual Fixtures
Pseudo-admittance is introduced as a novel bilateral telemanipulation system that is designed to mimic proportional-velocity admittance control on systems where the master is an impedance-type robot. The controller generalizes to systems with slave robots of the impedance or admittance type. Pseudo-admittance uses a proxy with admittance dynamics combined with direct force feedback from the sla...
متن کاملActive Control method for Postural Tremor via Iterative Learning Algorithm
This paper presents the behavior and the effective way to suppress the human hand postural tremor using the active force control method. The main advantages of proposed method include; its simple control technique, practically applicable in real-time due to the much lesser computational burden and the extra robustness feature the method generates. The actual tremor data from a Parkinson disease...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- IEEE transactions on rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society
دوره 8 1 شماره
صفحات -
تاریخ انتشار 2000