Frequency Dependence of Mouse Brain Tissue Stiffness Measured in vivo with MR Elastography
نویسندگان
چکیده
Introduction Magnetic resonance elastography (MRE) is a non-invasive imaging technique for quantitative measurement of the mechanical properties of biologic tissue in vivo [1]. The clinical interest in MRE has largely been driven by the direct relationship between tissue health and stiffness. As a result, MRE may provide significant clinical value for the non-invasive diagnosis of pathology and response to therapy by tracking tumor development and monitoring therapeutic response. MRE may also have considerable value in the development of treatment protocols in pre-clinical, rodent models of cancer. Because of cost and versatility, the mouse, in particular, is widely employed in oncologic studies. To resolve its small anatomic features, MRE experiments in mice must be performed with high driving frequencies (>600 Hz). However, high-frequency waves exhibit increased attenuation, reducing wave penetration depth and making it more difficult to impart motion deep into tissue with sufficient amplitude to overcome background noise. Also, biologic tissue is viscoelastic; hence, its response to load depends on the driving frequency. Recent MRE studies in mouse brain have been performed in high-field scanners (7 11.7T) at single driving frequencies of 1000 and 1200 Hz [2,3]. Here, we perform elastography in mouse brain tissue at 4.7T and report viscoelastic material properties over a range of driving frequencies (600 1800 Hz). Methods Acquisition: All experiments were conducted at 4.7T using a Varian DirectDrive small-animal MR scanner. The scanner is built around an Oxford horizontal-bore magnet, and is equipped with Magnex high-performance gradients and IEC gradient power amplifiers. MRE data were collected using an actively decoupled surface (receive)/volume (transmit) coil pair. Six female nude mice, 7 to 8 weeks-old, (Hsd:Athymic Nude-Foxn1, Harlan) were studied. All procedures were approved by the institutional Animal Studies Committee in accordance to the NIH Guide on the Care and Use of Animals. A custom-built stereotaxic head holder incorporated a piezoceramic-actuated (APA100M-NM, Cedrat Technologies) bite bar to introduce propagating shear waves into the brain (Fig 1, top). A TTL-equipped function generator and low-current voltage amplifier were used to drive the actuated bite bar harmonically at 600, 800, 1200, and 1800 Hz. Motion-encoding gradients were synchronized with actuator vibration to encode an isochromatic phase shift proportional to tissue displacement, at four time points, using a custom phase-locked spin-echo pulse sequence [2]. Two sets of motion-encoded data were acquired; one each with positive and negative polarity motion encoding gradients. The entire mouse brain was imaged with 29 contiguous trans-axial slices. The acquired in-plane resolution was 250 x 250 μm; the slice thickness was 500 μm. TR/TE: 1000/27.5 ms. In order to hold TR/TE constant for all data sets, the number of MR motion encoding cycles (NMS) varied with driving frequency. NMS = 4, 5, 8, and 10 for 600 Hz, 800 Hz, 1200 Hz, and 1800 Hz, respectively. Sinusoidal, motion encoding gradients with amplitudes of 18 G/cm were used at all driving frequencies. In this study, only through-plane uz(x,y) displacements were sensitized. Data processing: Data from a central region of the brain were interpolated in all three dimensions to yield isotropic voxels that were 125 μm on a side. Motion-sensitized, phase-contrast images were obtained by complex division of positive and negative polarity phase images. Parasitic phase wrapping was removed via commercial software (Phase Vision Ltd, Loughborough, UK). Phasecontrast data were converted into displacements, uz(x,y,t), by standard methods and the fundamental harmonic coefficient Uz(x,y,ω) was extracted by Fourier transform along the time dimension. Both real and imaginary parts of Uz(x,y,ω) were retained. Uz(x,y,ω) was smoothed with a circular, 2-order Butterworth bandpass filter (in: 0.158 mm, out: 0.630 mm) in the spatial frequency domain. A central difference scheme was used to approximate the Laplacian; ∆Uz(x,y,ω). Inversion of the linear isotropic homogeneous material equation of motion, (G' + iG'')∆Uz(x,y,ω) = -ρωUz(x,y,ω), was performed by local least-squares fit. For each voxel, the complex modulus was found that minimized the squared error between this equation and data from a 3-D kernel surrounding that voxel. The residual error of each fit, normalized by the variance in that kernel, was calculated to assess the "goodness-of-fit" of the linear isotropic homogeneous material model at that location. A normalized residual error (NRE) of zero indicates a perfect local fit; a residual of 1.0, a poor fit. All modulus approximations were thresholded; if the local model fit produced an NRE > 0.5, the estimated modulus was discarded. Results Standing wave fields shown in Figure 1 (middle) indicate motion initiating from the actuated bite bar penetrated with sufficient amplitude into the brain at all driving frequencies. Note that the wavelength decreases as the actuation frequency increases. However, subtle evidence of material stiffening with increasing frequency is evident in the wave images, since driving frequency and wavelength are inversely proportional for a material with constant density and stiffness. One would expect a 3:1 ratio in wavelength between driving frequencies of 600 and 1800 Hz. Representative storage modulus elastograms quantitatively depict global stiffening within brain tissue as frequency increases. Evidence of a strong frequency dependence in the average storage (G') and loss (G'') moduli of brain tissue is shown in Figure 1 (bottom). Variability in the mean modulus increases with driving frequency; however, this does not invalidate the observed trend. Discussion Results indicate mouse brain tissue exhibits pronounced frequency-dependent stiffening from 600-1800 Hz. This stiffening hinders efforts to increase the spatial resolution of MRE elastograms, since wavelength does not shorten in direct inverse proportion to frequency. However, the frequency dependency itself highlights dynamic properties of brain tissue subjected to high strain rates, and may provide an additional MRE-based diagnostic marker. Future work will assess the sensitivity of tissue viscoelasticy to disease or injury and therapeutic treatment over this actuation bandwidth. References [1] Muthupillai et al., Science, 1995, 269:1854-57; [2] Atay et al., J Biomech Eng., 2008, 130(2):21013. [3] Diguet et al., Proc ISMRM, 2009, 714. Figure 1: (Top) Custom head holder with piezoactuated bite bar introduces shear waves into brain; (Middle) Images of anatomy, wave displacement (Re{Uz(x,y,ω)}) with scaling factor, and storage modulus elastogram at 4 different driving frequencies; (Bottom) Mean storage and loss moduli as a function of actuation frequency; bars indicate standard deviation.
منابع مشابه
Magnetic resonance elastography of the brain
The purpose of this study was to obtain normative data using magnetic resonance elastography (MRE) (a) to obtain estimates of the shear modulus of human cerebral tissue in vivo and (b) to assess a possible age dependence of the shear modulus of cerebral tissue in healthy adult volunteers. MR elastography studies were performed on tissue-simulating gelatin phantoms and 25 healthy adult volunteer...
متن کاملMR Elastography-Derived Shear Stiffness Could Be Biomarker for IVD Degeneration
In a cross-sectional study, published in Radiology, in vivo lumbar MR elastography was performed once in the morning and once in the afternoon in 47 subjects without low back pain. Patients were ages 20 to 71 years. Researchers used principal frequency analysis to assess degeneration grade and MR elastography-derived sheer stiffness of the nucleus pulposus and annulus fibrous regions of all lum...
متن کاملFrequency-dependent viscoelastic parameters of mouse brain tissue estimated by MRE
Viscoelastic properties of mouse brain tissue were estimated non-invasively, in vivo, using magnetic resonance elastography (MRE) at 4.7 T to measure the dispersive properties of induced shear waves. Key features of this study include (i) the development and application of a novel MR-compatible actuation system which transmits vibratory motion into the brain through an incisor bar, and (ii) the...
متن کاملMR Elastography of the Brain in a Mouse Model of Alzheimer's Disease
Introduction Magnetic resonance elastography (MRE) is a technique that uses MRI to noninvasively measure tissues stiffness [1]. Shear waves are introduced via a mechanical actuator, imaged using a phase-contrast MRI sequence, and then mathematically inverted to calculate tissue stiffness. Recently MRE has been investigated in the brain for its potential to detect diffuse diseases that are curre...
متن کاملTREMR: Table-resonance elastography with MR.
Magnetic resonance elastography (MRE) is a noninvasive method of measuring tissue compliance. Current MRE methods rely on custom-built hardware to elicit vibrations that are tracked by MR imaging. Knowledge of the wave propagation can be used to calculate the local shear stiffness of the tissue. We sought to determine whether the vibrations of the patient table that result from low-frequency sw...