Dosimetric comparison of intensity modulated and volumetric arc radiation therapy for gastric cancer

نویسندگان

  • ZHIPING LI
  • JIANSHUANG ZENG
  • ZI WANG
  • HONG ZHU
  • YUQUAN WEI
چکیده

The aim of the present study was to compare radiotherapy treatment plans for gastric cancer using intensity-modulated radiotherapy (IMRT) and single/double-arc volumetric modulated arc therapy (SA/DA-VMAT) delivery techniques. A total of 29 postoperative gastric cancer patients were enrolled in this study and each patient was scheduled 5-field IMRT (5F-IMRT), 7-field IMRT (7F-IMRT), SA-VMAT and DA-VMAT techniques. Dose-volume histogram statistics, conformal index (CI), homogeneity index (HI) and monitor units (MUs) were analyzed to compare treatment plans. The DA-VMAT plans exceeded the other three methods in terms of planning tumor volume dose and organs at risk in the kidneys, but not in the liver. DA-VMAT exhibited a better mean CI (0.87±0.03) and HI (0.10±0.01) than the other techniques. In addition, for the kidneys the dose sparing (V13, V18 and mean kidney dose) was improved by DA-VMAT plans. Similar results were observed for MUs. However, 5F-IMRT showed a marginal advantage in V30 and mean dose in normal liver when compared with DA-VMAT. The results of this study suggest that DA-VMAT provides improved tumor coverage when compared with 5F-IMRT, 7F-IMRT and SA-VMAT; however, DA-VMAT exhibits no advantage in liver protection when compared with 5F-IMRT. Further studies are required to establish differences in treatment outcomes among the four technologies.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetric Evaluation of Volumetric Modulated Arc Therapy (VMAT) and Intensity Modulated Radiotherapy (IMRT) Using AAPM TG 119 Protocol

Background: The commissioning accuracy of Volumetric Modulated Arc Therapy (VMAT) need to be evaluated.Objective: To test and evaluate commissioning accuracy of VMAT based on the TG 119 protocols at local institution. Material and Methods: The phantom, structure sets, VMAT and IMRT beam parameter setup, dose prescriptions and planning objectives were following TG 119 guidelines to c...

متن کامل

Comparison of Volumetric Modulated Arc Therapy and Three-Dimensional Conformal Radiotherapy in Postoperative High-Grade Glioma: A Dosimetric Comparison

Introduction: We aimed to dosimetrically compare three-dimensional conformal radiotherapy (3D-CRT) and volumetric modulated arc therapy (VMAT) in terms of planning target volume (PTV) coverage, organ at risk (OAR) sparing, and conformity index (CI). Material and Methods: Planning data of 26 high grade glioma (HGG) patients were used. Prescrib...

متن کامل

Dosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma

Background: In the treatment of prostate cancer, radiotherapy is the potential to increase second primary cancers such as bladder and rectal cancers. The reasons for this potential are more monitor units (MUs), therefore a larger total body dose because of leakage radiation, a bigger volume of normal tissue is exposed to lower radiation doses. This study was designed to compare the integral dos...

متن کامل

Volumetric Modulated Radiation Therapy and Intensity Modulated Radiation Therapy for Lung Cancer: Literature Review

Intensity modulated radiation therapy (IMRT) and volumetric intensity-modulated arc therapy (VMAT) are two commonly used modalities to treat lung cancer. VMAT has established increasing interest in treating cancer due to shorter treatment delivery time and less number of monitor units (MUs). The main purpose of this article was to review the relevant current literature on planning studies for l...

متن کامل

Dosimetric comparison of volumetric modulated arc therapy and three dimensional conformal radiotherapy in the adjuvant setting for the management of gastric cancer: target volume coverage and normal tissue sparing

.............................................................................................................................. 4 List of Figures and Tables .............................................................................................. 6 Abbreviations .................................................................................................................... 7 Introductio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال: