Sympathetic neural and hemodynamic responses to upright tilt in patients with pulsatile and nonpulsatile left ventricular assist devices.

نویسندگان

  • David W Markham
  • Qi Fu
  • M Dean Palmer
  • Mark H Drazner
  • Dan M Meyer
  • Brian T Bethea
  • Jeffrey L Hastings
  • Naoki Fujimoto
  • Shigeki Shibata
  • Benjamin D Levine
چکیده

BACKGROUND Left ventricular assist devices (LVADs) are now widely accepted as an option for patients with advanced heart failure. First-generation devices were pulsatile, but they had poor longevity and durability. Newer generation devices are nonpulsatile and more durable, but remain associated with an increased risk of stroke and hypertension. Moreover, little is understood about the physiological effects of the chronic absence of pulsatile flow in humans. METHODS AND RESULTS We evaluated patients with pulsatile (n=6) and nonpulsatile (n=11) LVADs and healthy controls (n=9) during head-up tilt while measuring hemodynamics and muscle sympathetic nerve activity. Patients with nonpulsatile devices had markedly elevated supine and upright muscle sympathetic nerve activity (mean±SD, 43±15 supine and 60±21 bursts/min at 60° head-up tilt) compared with patients with pulsatile devices (24±7 and 35±8 bursts/min; P<0.01) and controls (11±6 and 31±6 bursts/min; P<0.01); however, muscle sympathetic nerve activity was not different between patients with pulsatile flow and controls (P=0.34). Heart rate, mean arterial pressure, and total peripheral resistance were greater, whereas cardiac output was smaller, in LVAD patients compared with controls in both supine and upright postures. However, these hemodynamic variables were not significantly different between patients with pulsatile and nonpulsatile flow. CONCLUSIONS Heart failure patients with continuous, nonpulsatile LVADs have marked sympathetic activation, which is likely due, at least in part, to baroreceptor unloading. We speculate that such chronic sympathetic activation may contribute to, or worsen end-organ diseases, and reduce the possibility of ventricular recovery. Strategies to provide some degree of arterial pulsatility, even in continuous flow LVADs may be necessary to achieve optimal outcomes in these patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Factors influencing the rate of flow through continuous-flow left ventricular assist devices at rest and with exercise.

T he heart failure (HF) community has witnessed a rapid evolution in mechanical circulatory support over the past decade. Following publication of the pivotal HeartMate II trials, continuous-flow left ventricular assist devices (cfLVADs) with an axial rotor (e.g., HeartMate II) quickly replaced the first-generation, pulsatile devices as both a bridge to transplant and as destination therapy for...

متن کامل

Are centrifugal ventricular assist devices the answer to reducing post-implantation gastrointestinal bleeding?

Ventricular assist devices (VAD) are an effective and innovative strategy for prolonging the life of patients with endstage congestive heart failure. However, significant rates of post-implantation nonsurgical bleeding continue to challenge the management of these patients (1). Over the last 15 years, VADs have transitioned from early pulsatile models to present-day nonpulsatile continuous-flow...

متن کامل

Patients with continuous-flow left ventricular assist devices provide insight in human baroreflex physiology.

The superior clinical outcome of new continuous-flow left ventricular assist devices (LVADs) challenges the physiological dogma that cardiovascular autonomic homeostasis requires pulsatile blood flow and pressure. We tested the hypothesis that continuous-flow LVADs impair baroreflex control of sympathetic nerve traffic, thus further exacerbating sympathetic excitation. We included 9 male heart ...

متن کامل

Therapy and Prevention Congestive Heart Failure

Studies in patients with congestive heart failure (CHF) have demonstrated an abnormal /3-adrenergic reflex vasodilation during orthostatic tilt. Baroreflex modulation of vascular resistance in patients with CHF was investigated during therapy with a vasoselective calcium antagonist, felodipinre. Eight patients on conventional therapy for severe CHF were studied after a 3 week course of addition...

متن کامل

Acquired von Willebrand syndrome after exchange of the HeartMate XVE to the HeartMate II ventricular assist device.

Instead of pulsatile ventricular assist devices an increasing number of nonpulsatile ventricular assist devices are introduced to clinical practice. The different flow characteristics of this new technique lead to alteration in shear stress on blood components, which may affect the coagulation system. Repeated von Willebrand factor analyses were performed in a patient who first was implanted wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation. Heart failure

دوره 6 2  شماره 

صفحات  -