The ultrastructure of the lens capsule abnormalities in Alport's syndrome.

نویسندگان

  • T Kato
  • Y Watanabe
  • K Nakayasu
  • A Kanai
  • Y Yajima
چکیده

The ultrastructure of lens capsule abnormalities in Alport's syndrome is reported. An anterior lens capsule from a 29-year-old patient with lenticonus who was affected by Alport's syndrome was obtained at the time of surgery. The histopathologic findings showed the thickness of the anterior lens capsule was decreased and there were many vertical capsular dehiscences localized at the inner part of the lens capsule. Almost every dehiscence was limited to the inner two thirds of the capsule. One should be cautious in attempting intraocular lens implantation into the lens capsule of patients with Alport's syndrome, because the lens capsule may be fragile in this disease.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ocular manifestations of Alport's syndrome: a hereditary disorder of basement membranes?

The ocular manifestations in 16 patients with Alport's syndrome were lenticonus and retinal flecks in the macula and mid periphery. These 3 features appear to be specific for this syndrome and are a considerable aid to diagnosis. Lens opacities are common, and other ocular abnormalities occur sporadically. The present evidence indicates that this is a hereditary, widespread disorder of basement...

متن کامل

Anterior lens capsule abnormalities in Alport syndrome.

Alport syndrome is a hereditary, progressive disease characterized by progressive nephritis, sensorineural deafness, and ocular abnormalities, including anterior lenticonus. The ultrastructure of the lens capsule abnormalities in Alport syndrome is reported. Four anterior lens capsules from 31-year-old patient and 26-year-old patient with lenticonus who were affected by the Alport syndrome were...

متن کامل

Evalauation of Laminin Expression during Mouse Lens Development

Introduction: Among the components of the extracellular matrix (ECM) and basement membrane (BM), laminitis heterotrimeric glycoprotein (laminin) and collagen type IV are the most important. In a previous study we have examined the role of collagen type IV in the developing lens capsule. The present study aims to determine the appearance and distribution of laminin in the BM and ECM of lenses ...

متن کامل

Detection of Herpes Simplex Virus DNA in Pseudoexfoliation Syndrome

Background: Pseudoexfoliation syndrome is one of the most common identifiable causes of open angle glaucoma. It has unknown etiology and pathogenesis. Infection, possibly viral, is one of the proposed pathogenic mechanisms in this condition. In the present study the presence of herpes simplex virus (HSV) in specimens of anterior lens capsule of patients with pseudoexfoliation syndrome has been ...

متن کامل

B-scan ultrasonography of ocular abnormalities: a review of 182 dogs

Ultrasonography is the only practical method for obtaining images of the posterior segment of the eye when the light-conducting media are opaque. In this study, 182 dogs with ocular abnormalities presented to the Department of Veterinary Surgery and Radiology from December 2008-August 2010 were included. All the animals were subjected to detailed ophthalmic examination and B-scan ultrasonograph...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Japanese journal of ophthalmology

دوره 42 5  شماره 

صفحات  -

تاریخ انتشار 1997