An array of highly flexible electrodes with a tailored configuration locked by gelatin during implantation—initial evaluation in cortex cerebri of awake rats
نویسندگان
چکیده
BACKGROUND A major challenge in the field of neural interfaces is to overcome the problem of poor stability of neuronal recordings, which impedes long-term studies of individual neurons in the brain. Conceivably, unstable recordings reflect relative movements between electrode and tissue. To address this challenge, we have developed a new ultra-flexible electrode array and evaluated its performance in awake non-restrained animals. METHODS An array of eight separated gold leads (4 × 10 μm), individually flexible in 3D, were cut from a gold sheet using laser milling and insulated with Parylene C. To provide structural support during implantation into rat cortex, the electrode array was embedded in a hard gelatin based material, which dissolves after implantation. Recordings were made during 3 weeks. At termination, the animals were perfused with fixative and frozen to prevent dislocation of the implanted electrodes. A thick slice of brain tissue, with the electrode array still in situ, was made transparent using methyl salicylate to evaluate the conformation of the implanted electrode array. RESULTS Median noise levels and signal/noise remained relatively stable during the 3 week observation period; 4.3-5.9 μV and 2.8-4.2, respectively. The spike amplitudes were often quite stable within recording sessions and for 15% of recordings where single-units were identified, the highest-SNR unit had an amplitude higher than 150 μV. In addition, high correlations (>0.96) between unit waveforms recorded at different time points were obtained for 58% of the electrode sites. The structure of the electrode array was well preserved 3 weeks after implantation. CONCLUSIONS A new implantable multichannel neural interface, comprising electrodes individually flexible in 3D that retain its architecture and functionality after implantation has been developed. Since the new neural interface design is adaptable, it offers a versatile tool to explore the function of various brain structures.
منابع مشابه
A tailored biocompatible neural interface for long term monitoring in neural networks
Neural interface electrodes that can record from neurons in the brain for long periods of time will be of great importance to unravel how the brain accomplishes its functions. However, current electrodes usually cause significant glia reactions and loss of neurons within the adjacent brain parenchyma. To address this challenge, a novel, polymer-based neural probe, with protrusions tailored to t...
متن کاملFlexible Electrode Array for Retinal Stimulation
In this Work, ITO/PET (Indium Tin Oxide / Polyethylene Terephthalate) electrode structure which provides biocompatibility, mechanical stability and flexibility is fabricated. Flexible ITO/PET implantable electrode array for a retina has been developed. The electrode array is fabricated on a thin PET/ITO substrate and is encapsulated using, SU-8, an insulating material. PET substrate and SU-8 po...
متن کاملFlexible polyimide microelectrode array for in vivo recordings and current source density analysis.
This work presents implantable, flexible polymer-based probes with embedded microelectrodes for acute and chronic neural recordings in vivo, as tested on rodents. Acute recordings using this array were done in mice under urethane anesthesia and compared to those made using silicon-based probes manufactured at the Center for Neural Communication Technology, University of Michigan. The two electr...
متن کاملOn the Cerebral and Cerebellar Cortical Activities in the Rat
25 Cerebellum is a highly organized structure with a crystalline morphology that has always intrigued 26 neuroscientists. Much of the cerebellar research has been conducted in anesthetized animals, 27 particularly using ketamine/xylazine combination in rats. It is not clear how and to what extent the 28 cerebellar cortical circuitry is affected by this anesthesia. In this study, we recorded spo...
متن کاملMiniature carrier with six independently moveable electrodes for recording of multiple single-units in the cerebellar cortex of awake rats.
Ensemble recording in cerebellar cortex of awake rats presents unique methodological challenges not encountered when recording from the cerebral cortex or from deep brain structures with more homogeneous cell populations. Compared to the cerebral cortex, removal of dura over the cerebellum evokes pronounced swelling, and insertion of multiple closely spaced electrodes in the cerebellar cortex c...
متن کامل