Transmission of intrathoracic pressure to the intracranial space during cardiopulmonary resuscitation in dogs.

نویسندگان

  • A D Guerci
  • A Y Shi
  • H Levin
  • J Tsitlik
  • M L Weisfeldt
  • N Chandra
چکیده

Elevation of intrathoracic pressure during cardiopulmonary resuscitation generates carotid pressure and flow, but also increases intracranial pressure. This increase in intracranial pressure may limit cerebral blood flow. Therefore, we performed studies designed to quantify the extent of this transmission and to identify the mechanism of transmission of intrathoracic pressure to the intracranial space during cardiopulmonary resuscitation in dogs. Intracranial pressure increased during the chest compression phase of all modes of cardiopulmonary resuscitation tested. During simultaneous compression-ventilation cardiopulmonary resuscitation, change in intracranial pressure (mm Hg) = 0.33 change in intrathoracic pressure (mm Hg) + 2.02 (r = 0.86) and was not significantly different from the relationship observed during conventional cardiopulmonary resuscitation. The magnitude of transmission of intrathoracic pressure to the intracranial space was increased by binding the abdomen and by raising the baseline intracranial pressure. No single route accounted for transmission of intrathoracic pressure to the intracranial space during cardiopulmonary resuscitation. Intracranial pressure fluctuations were unrelated to either carotid arterial or jugular venous pressure, and were found instead to be the result of pressure transmission by blood in non-valved veins and by cerebrospinal fluid. This was determined by three maneuvers. First, obstruction of cerebrospinal fluid flow by ligation of the cervical spinal cord reduced intracranial pressure (P less than 0.001) and made the change in intracranial pressure equivalent to pressure changes at the confluence of the intracranial venous sinuses, without affecting pressure changes at the confluence of the intracranial venous sinuses. Second, ligation of the cervical spinal cord and one of the two longitudinal vertebral veins adjacent to the cervical cord reduced the pressure changes in the intracranial space and at the confluence of the intracranial venous sinuses to about 60% of the levels observed when the cervical cord alone was ligated. Thus, the non-valved longitudinal vertebral veins appear to be the vascular channels of critical importance to pressure transmission. Finally, pressure changes in the thoracic cerebrospinal fluid were increased (P less than 0.05) by cord ligation, even after exsanguination minimized pressure transmission via blood-filled channels, indicating direct transmission of intrathoracic pressure through intervertebral foramina to the cerebrospinal fluid.(ABSTRACT TRUNCATED AT 400 WORDS)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mechanisms of Blood Flow During Cardiopulmonary Resuscitation

Despite the widespread clinical appliciktion of cardiopulmonary resuscitation (CPR), the mechanism responsible for blood flow during this maneuver remains undefined, although it has been assumed that blood is squeezed from the heart by direct compression of the sternum. We studied the hemodynamics of CPR in 15 arrested dogs. During chest compression, pressures in the left ventricle, aorta, righ...

متن کامل

Mechanisms of blood flow during cardiopulmonary resuscitation.

Despite the widespread clinical appliciktion of cardiopulmonary resuscitation (CPR), the mechanism responsible for blood flow during this maneuver remains undefined, although it has been assumed that blood is squeezed from the heart by direct compression of the sternum. We studied the hemodynamics of CPR in 15 arrested dogs. During chest compression, pressures in the left ventricle, aorta, righ...

متن کامل

The physiology of external cardiac massage: high-impulse cardiopulmonary resuscitation.

In intact chronically instrumented dogs, left ventricular dynamics were studied during cardiopulmonary resuscitation (CPR). Electromagnetic flow probes measured cardiac output and coronary blood flow, ultrasonic transducers measured cardiac dimensions, and micromanometers measured left ventricular, right ventricular, aortic, and intrathoracic pressures. The dogs were anesthetized with morphine,...

متن کامل

Determinants and clinical significance of jugular venous valve competence.

We studied the function of right internal jugular vein valves during cardiac catheterization in 32 patients and external jugular vein valves in vitro from 13 dogs. Patients with normal central venous pressure had competent valves during cough-induced transvalvular pressure gradients of 52.4 +/- 8.6 mm Hg. Ten of 15 patients with elevated central venous pressure had either incompetent or absent ...

متن کامل

Augmentation of cerebral perfusion by simultaneous chest compression and lung inflation with abdominal binding after cardiac arrest in dogs.

Recent studies have demonstrated that for the same chest compression force during mechanical cardiopulmonary resuscitation (CPR), the carotid artery-to-jugular vein pressure gradient and carotid blood flow are increased when the phasic rise of intrathoracic pressure is enhanced by abdominal binding and simultaneous ventilation at high airway pressure with each chest compression (SCV). The objec...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation research

دوره 56 1  شماره 

صفحات  -

تاریخ انتشار 1985